INSTALLATION INSTRUCTIONS

REMOVAL OF OLD COUNTER AND RE-ASSEMBLY OF NEW

1.

DISCONNECT POWER FROM MACHINE. DETACH HANDWHEEL BY REMOVING SCREW

AND WASHER FROM MAIN FOLD ROLL SHAFT. REMOVE FOUR (4) BUTTON HEAD SCREWS

HOLDING OPERATOR SIDE GUARD TO FOLDER FRAME.

2.

TURN SPEED POT KNOB TO “0” AND REMOVE TWO (2) SET SCREWS HOLDING KNOB TO

POTENTIOMETER SHAFT. REMOVE NUT AND LOCKWASHER FROM POTENTIOMETER.

NOTE: THE SHAFT OF POTENTIOMETER IS USED AS A MECHANICAL ATTACHMENT OF THE

COUNTER FLANGE TO THE CONTROL PANEL. ALSO REMOVE NUT, FLAT WASHER AND LOCK

WASHER WHICH RETAINS THE OPPOSITE COUNTER FLANGE. AT THIS POINT CAREFULLY REMOVE

COUNTER FROM CONTROL PANEL SO AS NOT TO DAMAGE RED LENSE THAT IS ADHERED TO

CONTROL PANEL.

3.

DISCONNECT TWO (2) RED WIRES FROM POWER SUPPLY CIRCUIT BOARD TO “L1” AND

“N” ON TB1 OF SUB PANEL BELOW. THERE ARE FOUR (4) PLASTIC STANDOFF’S HOLDING

POWER SUPPLY CIRCUIT BOARD TO SUB PANEL. PINCH TOP PORTION OF STANDOFF’S AND

REMOVE POWER SUPPLY CIRCUIT BOARD.

4.

DO NOT REMOVE PHOTOEYE SENSOR FORM FOLDER!!! THE EXISTING SENSOR CABLE WITH

CONNECTOR WILL BE USED AND CONNECTED TO NEW BAUMFOLDER SENSOR INTERFACE.

5.

INSTALL NEW COUNTER PART NO. 268-593-01-00 INTO FOLDER. NOTE: THE NEW COUNTER

IS THE SAME CONFIGURATION AS THE OLD. BE CERTAIN NOT TO DAMAGE RED LENSE OF CONTROL

PANEL. ATTACH NUT, FLAT WASHER AND LOCK WASHER TO STUD OF CONTROL PANEL TO HOLD

BACK FLANGE. RE-INSTALL POTENTIOMETER TO OTHER FLANGE WITH LOCK WASHER AND NUT.

TURN SHAFT OF POTENTIOMETER COUNTER CLOCKWISE UNTIL IT STOPS, THIS PUTS POSITION

AT “0”. RE-INSTALL KNOB WITH INDICATER AT “0” AND TIGHTEN SET SCREWS.

6.

INSTALL NEW BAUMFOLDER SENSOR INTERFACE PART NO. FK7000304. PLUG THE SMALL WHITE

THREE(3) PIN CONNECTOR INTO BOTTOM OF COUNTER. AT THE OTHER END OF SENSOR INTERFACE

YOU WILL FIND A WHITE FOUR (4) PIN CONNECTOR, PLUG THIS INTO THE EXISTING SENSOR CABLE

COMING THROUGH FRAME. CONNECT CABLE WITH BLACK THREE (3) PIN CONNECTOR INTO

BACK OF COUNTER. CONNECT OPPOSITE END OF THIS CABLE AS FOLLOWS: CABLE WIRE #1

TO TB1-L1, CABLE WIRE #2 TO TB1-N. REMOVE RING TERMINAL FROM GREEN/YELLOW WIRE

AND ATTACH TERMINAL PART NUMBER 261-362-07-00 (SUPPLIED WITH KIT) TO WIRE, CONNECT

THIS WIRE TO ONE OF THE FREE GROUND TERMINAL TABS UP AND SLIGHTLY LEFT OF TB1.

7.

WHEN REPLACING OPERATOR SIDE GUARD INTERFERENCE MAY EXIST BETWEEN THE

BLACK THREE (3) PIN CONNECTOR OF COUNTER AND HEX STANDOFF SPACER ATTACHING SAFETY

COVER TO ELECTRICAL SUB PANEL. IN THIS CASE REMOVE SCREW AND WASHER FROM SAFETY

COVER AND DETACH HEX STANDOFF SPACER. RE-INSTALL SCREW AND WASHER REMOVED ABOVE

AND FASTEN CORNER OF ELECTRICAL SUB PANEL TO HEX STANDOFF LOCATED BETWEEN SUB

PANEL AND OPERATOR SIDE FRAME. REPLACE GUARD, APPLY POWER AND RESUME FOLDING.