11 TP10330

and OFF is in the down position. The connectors for the

PHOTO HEAD (scanner) and the BATCHER (Valve, Lift

Wheel etc) are locking connectors. They cannot be installed

incorrectly. The PHOTO HEAD input is a 4 pin white nylon or

5 pin round male connector and the BATCHER is a 4 pin

round black male connector.

The current rating of the BATCHER fuse may depend on the type

of device supplied. Replace only with the type supplied with the

DCU-600. The fuse on models with modular power connectors

is mounted internal. The fuse in these models should only be

replaced by qualified personal.

CAUTION: NEVER EXCEED THE FUSE

RATING AS THIS COULD CAUSE FIRE,

PERSONAL INJURY OR PERMANENT DAM-

AGE TO THE EQUIPMENT

Connect the DCU-600 ONLY to a 115 volt 15 amp

GROUNDED outlet for safety and correct operation.

BATTERY REPLACEMENT

Over a period of time and usage the batteries in all electronic

equipment should be replaced so the unit will continue to func-

tion properly. The DCU-600 uses the batteries to protect the

stored data when the power is off. We recommend replacing the

batteries every two (2) years. We suggest writing the date of

purchase in the manual and on the bottom of the case. As a re-

minder, record the battery replacement date (two years from

purchase) in both locations. You should up-date the replacement

date every two years, and have the batteries replaced by quali-

fied personnel.

Use ONLY DURACELL alkaline size AA battery.

-------------------------- CAUTION --------------------------

The unit MUST BE unplugged from the 115 volt outlet before

attempting to replace the batteries or any procedure which

requires the removal of the cover on the unit. The unit should not

be plugged back into a power outlet until the cover has been

secured back on the unit; OTHERWISE, YOU MAY EXPERI-

ENCE AN ELECTRICAL SHOCK or damage the unit.

SCANNER (optical sensor) The reflective modulated scanner

senses material by reflection of light (from the scanner) off of the

material being counted. This is usually mounted on a fold plate of

the folder, scanning between the frame. A magnet holds the

scanner in place. Two type of scanners are available, modulated

and non-modulated

CAUTION: The DCU series of counters and batch

counters will not work with the old style U shaped incan-

descent break beam photo arm.