SECTION VI B - TESTING THE MODULATOR

GO TO MODULATOR, INSPECT WIRING CONNECTOR.

DISCONNECT CONNECTOR AND TEST RESISTANCE

BETWEEN PINS ON MODULATOR. RESISTANCE

VALUES FOR BENDIX

®

M-22

MODULATOR.

HOLD TO COMMON:

READ 3.5 TO 5 OHMS

EXHAUST TO COMMON:

READ 3.5 TO 5 OHMS

EXHAUST TO HOLD:

READ 7 TO 10 OHMS

TEST EACH PIN TO VEHICLE GROUND AND NOTE NO

CONTINUITY.

REPLACE THE MODULATOR.

YES

REPEAT THE “INITIAL

START-UP PROCEDURE”

REPAIR OR REPLACE MODU-

LATOR WIRE HARNESS.

GO TO SECTION IV “INSPECTION FOR

ILLUMINATED LEDs” AND RETEST.

NO

YES

YES

NO

NO

EXHAUST COMMON HOLD

CONNECTOR ON M-22

MODULATOR.

RECONNECT CONNECTOR TO MODULATOR.

TURN IGNITION ON AND PASS MAGNET OVER

RESET ON EC-16

CONTROLLER. NOTE

REACTION OF RED LEDs.

RESISTANCE READINGS

CORRECT?

START HERE FROM

SECTION VI A

ARE ANY RED LEDs

ILLUMINATED?

SAME RED LEDs
ILLUMINATED?