Connecting the air lines – Bendix Commercial Vehicle Systems AD-SP SYSTEM PURGE AIR DRYER 10/04 User Manual

Page 14

Advertising
background image

14

FIGURE 13 - SC-PR

SINGLE CHECK PROTECTION VALVE INSTALLED IN MULTI-COMPARTMENT RESERVOIR

FRONT AXLE COMPARTMENT

REAR AXLE RESERVOIR

SC-PR

VALVE

SUPPLY COMPARTMENT

GOVERNOR

COMPRESSOR

FIGURE 11 - AIR SYSTEM WITHOUT AD-SP

SYSTEM PURGE AIR DRYER

FIGURE 12 - AIR SYSTEM WITH AD-SP

SYSTEM PURGE AIR DRYER

3. Locate an unused port in both the supply compartment

and front axle compartment of the multiple compartment
reservoir. Install the SC-PR

valve in the front axle

reservoir (or compartment). Connect the supply port of
the SC-PR

valve to either an unused port in the supply

compartment of the reservoir OR Tee into the line between
the AD-SP

air dryer and the supply compartment of

the reservoir. Note: Use 3/8" air brake tubing. Refer to
Figure 13.

CONNECTING THE AIR LINES

Important General Instructions

The instructions that follow apply to all installations of the
AD-SP

air dryer regardless of whether the AD-SP

air

dryer is replacing an existing air dryer or is being installed
on a vehicle that never had one installed.

If the vehicle is currently equipped with an air dryer some
additional considerations apply.

A. If the AD-SP

air dryer is replacing an integral purge air

dryer, such as the Bendix

®

AD-9

air dryer, on a vehicle

equipped with any compressor except the Cummins-
Holset type E & QE, all that is necessary is that the air
dryer be removed and the existing air lines be correctly
connected to the AD-SP

air dryer.

FRONT AXLE RESERVOIR

GOVERNOR

GOVERNOR

REAR AXLE SERVICE

COMPRESSOR

FRONT AXLE SERVICE

REAR AXLE RESERVOIR

SUPPLY RESERVOIR

COMPRESSOR

AD-SP

AIR

DRYER

SUPPLY

FRONT AXLE SERVICE RESERVOIR

SINGLE CHECK VALVE

SC-PR

VALVE

INTERNAL SINGLE CHECK VALVE