Troubleshooting – Bendix Commercial Vehicle Systems EC-13 TRAILER ANTILOCK CONTROL 8/07 User Manual

Page 11

Advertising
background image

11

Troubleshooting

SECTION I

TRAILER STATUS LAMP TESTING

REPEAT THE “INITIAL

START-UP PROCEDURE”.

START HERE

USING A JUMPER WIRE CONNECT PIN 3F TO 1A AND/

OR 2A. WITH THE CONNECTION IN PLACE NOTE THE

CONDITION OF TRAILER STATUS LAMP.

TRAILER STATUS LAMP ON?

NO

YES

REPLACE EC-13

CON-

TROLLER AND RETEST.

CHECK THE FOLLOWING IN THE ORDER PRESENTED AND

AFTER REPLACING OR TESTING EACH COMPONENT,

TEST THE STATUS LAMP OPERATION:

1. CHANGE TRAILER STATUS LAMP BULB

2. CHECK TRAILER STATUS LAMP WIRING-GROUND

3. CHECK CONTINUITY OF WARNING WIRE BETWEEN PIN

3F ON THE 30 PIN CONNECTOR AND THE TRAILER STATUS

LAMP SOCKET

EC-13

CONTROLLER

WIRE HARNESS CONNECTOR

WITH TRACTOR IGNITION OFF,

DISCONNECT 30 PIN WIRE HARNESS

CONNECTOR FROM EC-13

CONTROLLER

THEN TURN TRACTOR IGNITION ON AND

MAKE AND HOLD A BRAKE APPLICATION.

TRAILER STATUS

LAMP 3F

GROUND 1A & 2A

Advertising