Dc resistance, Figure 6 measuring resistance – Bird Technologies 8931-230SC13-Manual User Manual
Page 24
 
Bird 8930 Series Semiconductor Termaline Coaxial Load Resistor
14
DC Resistance
Measuring the dc resistance between the inner and outer conductors 
of the RF connector shows changes in the load over time, a good check 
of the load resistor’s condition. Under normal operating conditions, 
the resistor should provide at least 5,000 hours of operation before 
requiring any additional service. DC resistance tracking must start 
before the load is put into service, and should be measured annually.
Perform the following steps and record the value for future 
comparison. Make sure that you have an ohmmeter with an accuracy 
of ±1% at 50 ohms and that the load temperature is between 20 and 
25 °C (68 to 77 °F) before starting.
y
Turn off the RF power and interlock circuitry.
y
Disconnect the RF line.
y
Connect the multimeter test leads to the center and outer 
conductor of the load resistor. Refer to Figure 6.
y
Compare the measured value with the previous measurement and 
with the baseline resistance, measured when the load was put 
into service. If the new value differs from either of these by more 
than 1 ohm this could indicate a failing resistor.
Figure 6
Measuring
Resistance
WARNING
Never attempt to connect or disconnect RF equipment from the
transmission line while RF power is being applied.
Leaking RF energy is a potential health hazard.