Bird Technologies SCC7 Series-Manual User Manual

Page 32

Advertising
background image

18

Removing the Load

1.

Loosen the RF cables from the RF connectors on the load.

2.

Unplug the blower assembly. 

Note:

Step 2 is for blower equipped loads only.

3.

Remove the Cal Cart front panel. See “Removing the Front Panel” on page 4.

4.

Remove the screws on the sensor mounting bracket. See Figure 10 on page 17.

5.

Pull the sensor assembly back until the RF cable disconnects from the load.

6.

Replace the vent plugs with the shipping plugs.

7.

Remove the mounting bolts connecting the load to the Cal Cart.

8.

Remove the load.

Note:

The RF cable should disconnect when the load is moved.

Note:

To install a new load, reverse this procedure.

Figure 11 Removing the Load

WARNING

Heavy load. Do not attempt to lift unaided.

WARNING

Care should be used when handling the RF cable and connector. DO NOT pull, pry, or tug on the RF cable or 

connector. Otherwise, damage may occur to the cable housing and may cause a fire.

RF Cable

Power Plug

Load

Mounting Bolts