Broadcast power monitors, Bpme series, Applications bpme operating characteristics – Bird Technologies BPME Series-Datasheet User Manual

Page 3: Typical installation diagram, Specifications model 3129 broadcast power meter, Forward power range

Advertising
background image

Broadcast Power Monitors

BPME Series

Broadcast Power Monitors

BPME Series

APPLICATIONS

BPME OPERATING CHARACTERISTICS

Frequency Range See chart

Forward Power

Range

See chart

Measurement Type In-line, True Average Power

Peak/Average Ratio 10 dB

Coupler Directivity 26 dB min., 30dB Typical

Accuracy ±5% of reading

Alarms VSWR, No/Low Forward Power, High Forward Power

Outputs SPDT relay contact

Display Options BPME PC Software, 3129

Remote Interface Ethernet 10BASE-T or

100BASE-TX (auto-sensing)
Ethernet Version 2.0/IEEE 802.3
Protocols: ARP, UDP/IP, TCP/IP, Telnet,
ICMP, SNMP, DHCP, BOOTP, TFTP, Auto IP, and HTTP
Security: 256-bit encryption
Serial RS-232, 9600 baud, no parity,
8 data bits, 1 stop bit, no handshake

1. 3129 DIGITAL DISPLAY

2. RS-232 COMMUNICATION PORT, DB-9

3. POWER/ALARM CONNECTOR, DB15

4. ETHERNET CONNECTOR

(FOR NETWORK OR LOCAL PC)

5. COMPUTER

(NOT ON A NETWORK)

6. MONITOR PORT

7. MONITOR DEVICE

(SPECTRUM ANALYZER, MODULATION MONITOR,

OSCILLOSCOPE)

8. DETECTION/CONTROL MODULE

9. CELL PHONE OR PDA-INSTANT MESSAGE

NOTIFICATION OF ALARM

TYPICAL INSTALLATION DIAGRAM

Measuring RF power and system match characteristics can be made with the
BPME in any installation, regardless of the signal waveform. Complex waveforms
such as 8-VSB and COFDM, used in IBOC, DAB and HDTV systems, as well as FM,
AM and CW signals are accurately measured to ensure total power output
requirements.

HD Radio is combined with the analog signal at the input to the antenna. Analog
powercoupled to the digital transmitter must be considered when specifying
the BPME. The 20 dB dynamic range of the BPME will allow for easy high-level
combined installations.

HD Radio and an analog signal can use interleaved antennas for separate but
simultaneous transmission. High isolation reduces the mutual coupling however,
analog power coupled to the digital transmitter must be considered when
specifying the BPME. With 20 dB of dynamic range, the BPME is ready to handle
this type of installation.

Multi-station operation will have a high peak-to-average power ratio, depending
on the number of stations combined. Power meters not equipped to handle this
high ratio will display accuracy errors up to 20%. With the ability to accurately
read greater than 10 dB peak-to-average power, the BPME is your choice for
multi-station applications.

HIGH-LEVEL COMBINED

Transmitter

Transmitter

Combiner/Coupler

Load

Transmitter

Transmitter

Load

INTERLEAVED ANTENNA

Transmitter

Transmitter

Combiner/Coupler

Load

MULTI-STATIONS

SPECIFICATIONS

MODEL 3129 BROADCAST POWER METER

Operating Voltage 115/230 VAC @ 50/60 Hz

Operating Power Less than 10 watts

Dimensions 5.25" X 19" X 1.75"

(133.35 mm X 483 mm X 44.5 mm)

Weight Approximately 2 lbs. (0.85 kg)

Supplied with 50 feet of cable to connect RS-232 and serial

ports between 3129 and line section, and
serial interface cable

LINE SECTION

Operating Temp. 0°C to +50°C (32°F to 122°F)

Storage Temp. -20°C to + 80°C (-4°F to 176°F)

Humidity 95% ±5% max. (noncondensing)

Altitude up to 10,000 feet (3,048 m)

Calibration cycle Annual

Consult our Applications Engineers at Bird Technologies Group today for assistance in
choosing the BPME best suited for your installation.

Line Size Power Designator

VHF (45-230 MHz)

UHF (470-890 MHz)

7/8” Low

Medium
High

5W – 500 W
20 W – 2000 W
50 W – 5000 W

2.5 W – 250 W
10 W – 1000 W
25 W – 2500 W

1 5/8” Low

Medium
High

20 W – 2000 W
80 W – 8 kW
200W – 20 kW

5 W – 500 W
20 W – 2000 W
50 W – 5000 W

3 1/8” Low

Medium
High

50 W – 5000 W
200 W – 20 kW
500 W – 50 kW

25 W – 2500 W
100 W– 10 kW
250 W – 25 kW

4 1/16”

&

4 1/2”

Low
Medium
High

100 W – 10 kW
400 W – 40 kW
1000 W – 100 kW

40 W – 4 kW
150 W – 15 kW
400 W – 40 kW

6 1/8” Low

Medium
High

200 W – 20 kW
800 W – 80 kW
2000 W – 200 kW

80 W – 8 kW
300 W – 30 kW
750 W – 75 kW

FORWARD POWER RANGE