Chapter 4

Operating Instructions

General

The Model 8578A100GIG has no operating controls. When

installed the only requirement is for the interlock switch to

be connected to the RF power source. After applying an air-

flow

³

1000 ft

3

/min (28.32 m

3

/min) to the inlet grill the unit

is now ready to accept RF power. Once the unit is set, there

is no need for the presence of an operator.

Load Power

WARNING

Surface can reach temperatures in excess of 100°C

when maximim power is applied to load.

WARNING

Limit the interlock terminal to less than 30 Vrms.

Although the interlock terminal is rated to 230 Vac,

the potential for electrical shock exists.

CAUTION

Do not apply more than the rated RF power to the

load. Excessive RF power will damage the load resistor.

Do not operated above the rated capacity; i.e. 10kW of

power. The unit will handle a small percentage of overload

until the interlock system’s sensor relay opens due to over

temperature and turns off the transmitter. If a large

amount of overloading occurs, resistor failure is eminent be-

fore the interlock system reacts.

Shortly after load power has been applied, the RF line may

be too hot to touch. Disconnect only while following the Shut

Down procedure.

Operation

Under

Normal and

Abnormal

Conditions

The interlock is for proper operation at the maximum rated

ambient condition of 40°C (104°F).

The normally closed relay opens at 86°C ± 3°C (186.8°F

±5.4°F) and closes at 80°C ±3°C (176°F ±5.4°F).

Shut Down

When operation of the load has been completed, follow these

steps for shut down.

1. Turn transmitter off.