Chapter 3
Calibration
Calibration Accessories
Calibration Combination including:
y
One 50 ohm load
y
One Open standard
y
One Short standard
Test Cable (optional) – Phase-stable for reliable,
consistent results.
☞
NOTE: If a test cable is used to connect the Site
Analyzer system under test, attach the standards
to the end of the test cable during calibration.
Calibrating
Press key
from either
Measure
Match or
Fault
Location
mode
825.00
MHz
841.00
Calibration Mode
Calibration: Off
1.70
1.00
VSWR
Open
Short
Load
Cal Done