NOTE: A tapped heat sink can be used instead
of using a washer and nut.
3. To ensure a proper thermal contact, torque the
mounting screws to 25 to 30 inch-pounds.
WARNING
Never attempt to connect or disconnect the equipment
from the transmission line while RF power is being
applied. Leaking RF energy is a potential health hazard
4. Using a suitable cable, as short as convenient, at-
tach the RF power source to the load with a mat-
ing connector.
5. Tighten all connections.
6. Ensure the heat sink has ventilation adequate to
maintain the loads body temperature to a maxi-
mum of 155°C (311°F) on top.
Models 8072A-1 & 8072A-2
Termaline RF Coaxial Load Resistor
2
1.400
O.C.
2.000
1.719
1.250
.344
3.656
.181 DIA. THRU HOLES
6 PLACES