Specifications – Bird Technologies 8930 Series User Manual
Page 33

Maintenance
23
Specifications
Frequency Range
dc – 1000 MHz
Power Rating
10 kW continuous duty
Peak Power for Pulse Width
*
1 µs
10 µs
100 µs
1000 µs
5000 µs
150 kW
120 kW
85 kW
55 kW
30 kW
Impedance
50 ohms
VSWR
dc – 400 MHz
400 – 1000 MHz
1.15 max
1.2 max
Connectors
8931
8932
8936
8937
8938
Female LC
1-5
/8” EIA Flanged
3-1
/8” EIA Flanged
3-1
/8” Unflanged
3-1
/8” Unflanged, Recessed Center Conductor
AC Power
–115
–230
115 V +10, –6% @ 50/60 Hz ±3%
230 V +10, –6% @ 50/60 Hz ±3%
AC Line Power Rating
460 W max
Fuse Rating
IEC (5 x 20 mm) Type T
115 Vac
230 Vac
3.15 A
1.25 A
Thermoswitch
Interlock
Fan Control
Normally closed. Opens at 226 °C (439 °F)
Normally open. Closes at 60 °C (140 °F)
Thermoswitch Rating
115 Vac
230 Vac
10 A
5 A
Ambient Temperature
†
– 40 to +45 °C (– 40 to +113 °F) @ 60 Hz
– 40 to +40 °C (– 40 to +104 °F) @ 50 Hz