Cancelling a pending no-motion alert, Cancelling a no-motion alert, About fall detection – Blackline GPS Loner SMD User Manual

Page 17: Cancelling a pending fall detected alert, Cancelling a fall detected alert

Advertising
background image

15

Cancelling a Pending No-motion Alert

1. Press the acknowledge button for 1 second.

After one second, the alarm pattern will be silenced and Loner SMD will return to
regular operation.

If you have not cancelled the alert within 30 seconds, the No-motion Alert is sent, initiat-
ing the alert escalation process. Loner SMD will annunciate the high alarm pattern and will
continue until the alert is canceled or the battery is depleted.

Cancelling a No-motion Alert

1. Press and hold the acknowledge button for 3 seconds.

After three seconds, the alarm pattern will be silenced and Loner SMD will return to
regular operation.

™

If the user cancels a No-motion Alert, this does not clear the alert within the Loner
Portal user account. Monitoring personnel are required to address the safety incident.

About Fall Detection

Loner SMD is constantly monitoring your motion for falls. If Loner SMD detects a fall, it will
enter the alarm mode and annunciate the low alarm pattern to indicate a pending Fall
Detected alert. If you do not require assistance, you have 30 seconds to cancel the alert.

Cancelling a Pending Fall Detected Alert

1. Press the acknowledge button for 1 second.

After one second, the alarm pattern will be silenced and Loner SMD will return to
regular operation.

™

If you have not cancelled the alert within 30 seconds, the Fall Detected Alert is sent,
initiating the alert escalation process. Loner SMD will annunciate the high alarm pattern
and will continue until the alert is canceled or the battery is depleted.

Cancelling a Fall Detected Alert

1. Press and hold the acknowledge button for 3 seconds.

After three seconds, the alarm pattern will be silenced and the Loner SMD will
return to regular operation.

™

If the user cancels a fall detected alert, this does not clear the alert within the Loner
Portal user account. Monitoring personnel are required to address the safety incident.