— 7 —
Washer
Hood
Gap
Truss head screws,
lockwashers and nuts
Table
S/S
Attach Table to Tank
22" MIN.
23-3/8"
DISHTABLE DIMENSION INFORMATION
LEFT SIDE TABLE
Right side table (not shown) –
dimensions are same but reversed
FRONT TABLE
(Corner installation only)
Notch for
Hood Handle
1"
25-3/4"
26-3/4" MIN.
1"
4" MAX.
6"
4" MAX.
4" MAX.
Electrical Connections
WARNING
Before performing any service that involves electrical
connection or disconnection and/or exposure to
electrical components, always perform the Electrical
LOCKOUT/TAGOUT Procedure. Disconnect all circuits.
Failure to comply with this procedure can cause
property damage, injury or death.
Refer to the unit’s data plate before making any
connections.
POWER REQUIREMENT
MOD.
VOLTS
W-2-20878
SER. NO.
PH.
HZ.
AMP.
HP.
BRANCH CIRCUIT PROTECTION REQUIREMENT
SUPPLY CIRCUIT CONDUCTORS (MINIMUM AMPACITY)
CIRCUIT-BREAKERS (MAZIMUM AMPACITY)
TIME-DELAY FUSES (MAZIMUM AMPACITY)
Any connections must correspond to the information
specified on the data plate. A fused disconnect switch
or circuit breaker (not supplied) MUST be installed in
the electrical supply line for the dishwasher. This service
connection must meet all local and national electrical code
requirements. All connections are made at one common
location in the control box. The control box cover is hinged
and can be opened by removing six (6) ¼ -20 screws and
swinging the cover to the right.
Thermostat –
Turn screw clockwise to
increase temperature;
Turn counterclockwise to
decrease temperature
Incoming
power
connection
Thermostat & Power Connection Locations
Note: If the unit has the optional electrical booster,
refer to section on Boosters for separate electrical
connection information.