Additional Features:
Never thought you would ever see so many nifty neato features in a strobe light did you?
Temperature:
IMPORTANT - Brightness will decrease when the LED temperature rises over 55ºC.
If a temperature of +70ºC is reached, the overheat protection sensor will activate,
initiating blackout until a safe temperature is reached. It’s highly recommended
to not use the LEDs at full strobe brightness for longer than a 1 minute
period. You can safely use the fixture as a normal wash in 3/9 pixel modes
which are programmed to achieve a max of 40% strobe brightness.
1.) Press the <UP/DOWN> buttons until you reach Temp.
2.) Push the <ENTER> button.
3.) The display will show the current temperature in Celsius degrees.
Signal Loss Settings:
In the event of DMX signal loss, you can set the fixture to either hold its last
received DMX signal values, or clear them.
1.) Press the <UP/DOWN> buttons until you reach Config.
2.) Push the <ENTER> button.
3.) Using the <UP/DOWN> buttons, navigate to DMX Status, then press the
<ENTER> button.
4.) Use the <UP/DOWN> buttons to select either Value Hold, or Value Clear.
5.) Press the <ENTER> button to confirm.
LCD Display On/Auto Off:
Display mode On will keep the LCD illuminated continually, Auto will shut the display
off after 30 seconds of inactivity.
1.) Press the <UP/DOWN> buttons until you reach Config.
2.) Push the <ENTER> button, and navigate to Display Mode.
3.) Push the <ENTER> button, then select either On or Auto, and press the
<ENTER> button.
Key (Button) Protection Mode:
With Key Lock active, buttons will be unresponsive to any initial button press after
30 seconds of inactivity. Temporary unlock will occur with more than 1 button
press. To disable this feature, activate Key Unlock.
1.) Press the <UP/DOWN> buttons until you reach Config.
2.) Push the <ENTER> button.
3.) Press the <UP/DOWN> buttons until you reach Key Mode, then press
<ENTER>.
4.) Use the <UP/DOWN> buttons to select either Key Lock, or Key Unlock, and
press the <ENTER> button.
Test Mode:
1.) Press the <UP/DOWN> buttons until you reach Test LED.
2.) Push the <ENTER> button.
3.) Now, you can choose to test all of the LEDs at once, or individually test each
of its 9 segments. Use the <UP/DOWN> buttons to navigate, and press the