Page 12, D001, Addr – Blizzard Lighting RokPix (Rev A) User Manual

Page 9: Chnd, Flas or fade, Fl00-fl15, Fa00- fa15, As00-as15, Sp15, Sp00

Advertising
background image

Page 12

R

okPix Manual R

ev

. A

© 2013 Blizzard Lighting, LL

C

DMX Mode

Allows the unit to be controlled by any universal DMX controller.

1.) The default mode for the

fi

xture is DMX, which appears as

d001

on the LED readout. T

o

select

a different DMX address, using the

<MENU>

button, select

Addr

,then hit

<ENTER>

. Use the

<UP/DOWN>

buttons to select the correct address, then hit

<ENTER>

to con

fi rm.

Setting the DMX Channel Mode:

1.) T

o

select a DMX channel mode, press the

<MENU>

button, then use the

<UP>

or

<DOWN>

buttons until the displa

y reads

Chnd

and press the

<MENU>

button. Then use the

<UP>

or

<DOWN>

buttons until the displa

y reaches y

our desired channel mode. Press the

<MENU>

button

to con

fi rm

.

Stand-Alone, Master/Slave, Sound Active Modes:

Allows a single or Master/Slaved units to run factory installed programs at user selectable speeds.

1.) T

o

set the

fi

xture in Flash/F

ade mode, select

FLAS or FAdE

. T

o

con

fi

rm, press the

<EN-

TER>

button.

2.) Now

, y

ou can adjust the

fl

ash settings from

FL00-FL15

or the fade settings from

FA00-

FA15.

Then press the

<ENTER>

button to con

fi rm.

3.) T

o

use the

fi

xture in automatic mode, select

ASC-

, and press the

<ENTER>

button. Then use

the

<UP/DOWN>

to choose from

AS00-AS15

, then press the

<ENTER>

button to con

fi rm.

4.) Adjust the speed of the chase as abo

ve

using

SP15

(slowest) to

SP00

(fastest) then press the

<ENTER>

button to con

fi rm.

5.) T

o

set the

fi

xture as a sla

ve

unit, select

SLAU

, and hit

<ENTER>

. The unit will displa

y a

fl ash-

ing

SL.AU

to indicate it is in sla

ve

mode.

Sound Active Mode:

1.) T

o

use sound activ

e mode, select

SouA

, then press the

<ENTER>

button. Then use the

<UP/

DOWN>

buttons to choose

Sou1

or

Sou2.

Press the

<MENU>

button to con

fi rm

.

Standalone (Program) Mode:

Allows a single unit to display a variety of colors and programs without a DMX controller.

1.) T

o

set the

fi

xture in manual mode, select

Pr--

. T

o con

fi

rm, press the

<ENTER>

button.

2.) Now

, select the progr

am by using the

<UP>

and

<DOWN>

buttons to select

Pr00-Pr21

. T

o

con

fi

rm, press the

<ENTER>

button.

Pr00-Pr12

are static colors. Adjust the chase speed by

using the

<UP>

and

<DOWN>

buttons to na

vigate to

SP-- ,

and press the

<ENTER>

button.

Then select from

SP00-SP15

(fast <--> slow).

Manual Color Adjustment:

Allows the user to adjust the color balance of the

fi

xture. These settings are global, they will effect all modes.

1.) Use the

<MENU>

and

<UP/DOWN>

button to select

rL--

(R

ed Lev

el),

GL--

(Green Lev

el),

bL--

(Blue Lev

el) or

UL--

(White Lev

el), then hit

<ENTER>

.

2.) Using the <UP/DOWN> buttons, select the maximum lev

el for each color between

x000-

x255

(000=off

), then hit

<ENTER>

to con

fi rm.

Page 9

R

okPix Manual R

ev

. A

© 2013 Blizzard Lighting, LL

C

Fixture Linking (Master/Slave Mode)

1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the

fi rst

fi xture.

2. Connect the end of the cable coming from the fi rst

fi

xture which will ha

ve

a (female) 3 pin connec

-

tor to the input connector of the next

fi xture

con-

sisting of a (male) 3 pin connector

. Then, proceed

to connect from the output as stated abo

ve

to the

input of the following

fi

xture and so on.

A quick note:

Often,

the setup for Master

-

Sla

ve

and Standalone

oper

ation requires that

the

fi rst

fi

xture in the

chain be initializ

ed for

this purpose via either settings in the control panel or DIP-switches. Secondarily

, the

fi xtures

that follow ma

y also re-

quire a sla

ve

setting.

Check the “

Operating Adjustments

” section in this manual for com-

plete instructions for this type of setup and con

fi gur

ation.

Mounting & Rigging

This

fi

xture ma

y be mounted in an

y S

AFE position pro

vided there is

enough room for v

entilation.

It is important nev

er to obstruct the fan or v

ents pathw

ay

. Mount the

fi

xture using a suitable “C” or “O” type clamp

. The clamp should be

rated to hold at least 10x the

fi

xture’

s weight to ensure structur

al sta-

bility

. Do not mount to surfaces with unknown strength, and ensure

properly “r

ated” rigging is used when mounting

fi xutres

ov

erhead.

Adjust the angle of the

fi

xture by loosening both knobs and tilting the

fi xture.

After

fi

nding the desired position, retighten both knobs.

• When selecting installation location, tak

e into consider

ation lamp

replacement access (if applicable) and routine maintenance.

• Safety cables MUST AL

W

A

YS be used.

• Nev

er mount in places where the

fi

xture will be exposed to r

ain,

high humidity

, extreme temper

ature changes or restricted v

entilation.

Advertising