Interface specifications DMX input/output interface:

3-pin-block as DMX signal interface.

DMX input and output interface

2: Optional RJ45 as signal

interface to each unit. Only one

interface can be used.

DMX Address code function setting
interface. Note ON is dip down.

Low voltage input:

Under normal circumstances only three channels are used with low voltage RGB LED lighting but a fouth channel is available for
another color if required.

Input: For low voltage power input (5VDC ~ 24VDC).
V- (negative) V+ (positive)

IMPORTANT NOTE:
COM: is for (+) Cathode
Ch1, CH2, CH3, CH4 are (-) Anode

WIRE 6-8 MM (0.25-0.30")

EXPOSED WIRE SHOULD NOT BE MORE THAN 6- 8 MM LONG & SOLDER TIP

(tinned). DO NOT ALLOW WIRES TO CROSS AND INSURE ALL EXPOSED WIRE IS

FULLY INSERTED INTO THE SCREW TERMINALS. HAND TIGHTEN SCREW

TERMINALS. USE ONLY 22 TO 16 GAUGE WIRE (NOT EXCEEDING 16 GAUGE) .

WARNING!

Input voltage must be identical to output voltage of the LED

+ +

-

-

-

-

-

-

If you’re attaching RGB Flex Strip to Komply™ DMX, correct
polarity is imperative; Black (may be white color wire) wire is
positive (+) and goes to “COM” terminal. The common format is
to insert the Red wire to CH1,Green wire to CH2 and Blue wire
to CH3 (RGB Format). If unit is set to DMX Channel 1, the unit
will automatically occupy Channels, 1,2,3 and 4 on the master
DMX console.

If attaching a single color, the format is to attach the positive to
COM and negative to Ch1 (but can also be Channel 2, 3 or 4 if
desired).

WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION.

TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER

SUPPLIES.

Failure to install the power supplies and/or LED modules in accordance with the National Electric Code (NEC), all applicable Federal, State and local electric
codes as well as the specific Underwriters Laboratories (UL/CSA) safety standards for the installation, location and application may cause serious personal
injury, death, property damage and/or product malfunction. These instructions are guidelines for installation and power supplies. Installation requirements may
vary depending on the application. Licensed electricians should provide all installation services for connection of both primary and secondary
(input/output) of the power supplies.
Not for in wall installation.
Cable lighting systems be installed only in dry locations
Cable lighting systems not be installed in bathrooms; Keep away from water or wet areas.
Conductors of extra-low-voltage circuits be rigidly supported,
Conductors not be installed in contact with combustible materials and not run through walls, ceilings, floors or partitions, and; Uninsulated conductors not be
installed less than 2.2 m from the floor.
When using power supplies; the following basic safety features should be verified in addition to any other application specific concerns and local safety codes:
Short circuit protection
Overload protection (FUSE 5 AMP)
Overheat protection
Correct output voltage, including consideration for ripple and spikes.

Komply™ DMX

LOW VOLTAGE DMX DECODER (12/24VDC)

LIGHTING

WWW.BLIZZARDLIGHTING.COM

Page 2/3