Clay Paky ALPHA WASH 700 (C61350) User Manual

Page 12

Advertising
background image

12

ALPHA WASH 700

2) Press

F

to reset partial lamp strikes hours, a confirmation message

(Are you sure ?) appears on the display.

3) Select YES to reset partial counter or NO to keep the current setting

and return to the top menu level

SYSTEM VERSION

Used for displaying the software and hardware version of each board
installed in the projector.
CPU brd (CPU board)
0: PT-3f (Pan / Tilt board)
1: 6-Ch (6 channel board)
2: 8-Ch (8 channel board)

BOARD DIAGNOSTIC

Used for displaying the status error of each board installed in the projector:
0: PT-3f (Pan / Tilt board)
1: 6-Ch (6 channel board)
2: 8-Ch (8 channel board)

DMX MONITOR

Used for displaying the projector DMX channel level in bit (Val) and in
percentage (Perc).

FANS MONITOR

Used for displaying the speed of each fan installed in the projector:
Ball. IN (Ballast IN Fan)
Eff.IN (Effects IN Fan)
Lamp (Lamp Fan)

NETWORK PARAMS

Allows the "Network" parameters of the projector to be displayed or:

IP address:

Internet Protocol address (two projectors must not have the

same IP address)

IP mask: 255.0.0.0
Mac address:

Media Access Control: the projector’s Ethernet Address

LAMP

Used for turning lamp on and off from the projector control panel.
1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

B

and DOWN

C

keys to turn the lamp on (On) or off (Off)

3) Press

F

to confirm the selection or LEFT

D

to keep current settings

and return to the top level.

RESET

Used for resetting the projector.
1) Press

F

to reset the projectors, a confirmation message (Are you sure

?) appears on the display.

2) Select YES to starting reset the fixture or NO to keep the current setting

and return to the top menu level.

CHANNEL

Used for setting channel levels from the projector control panel.
1) Press

F

- the first channel appears on the display.

2) Use the UP

B

and DOWN

C

keys to select the required channel:

3) Press

F

and use the UP

B

and DOWN

C

keys to select the

required DMX level (value between 0 and 255).

4) Press LEFT

D

to return to the top menu level.

MANUAL CONTROL

Lamp

Manual
Control

On

Off

No

Yes

Reset

Network

params

System
Version

Board Revis. Hw.rv.
CPU brd x.x.x x.x
com.dev x.x
0: PT-3f x.x x.x
1: 6-Ch x.x x.x
2: 8-Ch x.x x.x

Board

Diagnost.

Dmx

Monitor

Board Status Err%
0:PT-3f Good 0.00
1:6-Ch Good 0.00
2:8-Ch Good 0.00

Fans

Monitor

Fan Speed (RPM)
Ball.In. XXXX
Eff.In XXXX
Lamp XXXX

Channel

099100_AlphaWash700_Rv2_EN_ 23/02/11 17.06 Pagina 12

Advertising