background image

Section 22–Changing the Gain on a Variable-Gain TMA

ATC200-LITE-USB Teletilt

®

RET System

22-2

October

2014

Bulletin 639536 • Revision L

4. The

TMA Device …Operation screen will appear (Figure 22-2).

Note. TMA data (TMA Rx Band, TMA Tx Band, Min Gain, Max Gain, Gain Resolution and

Current Gain) from the device are displayed on this screen: This information may be used as

a reference to help to set the new Gain.

This screen will display the configurable parameter New Gain and Set Gain as disabled for

a Fixed Gain TMA and enabled for Variable Gain TMA.

5.

If the selected TMA is a Fixed Gain, the TMA Device dialog displays all the values only for

viewing (Figure 22-2). Click to close the dialog box to return back the Device Information list.

Note the following in Figure 22-2:

•

The ID of the device to be configured is displayed in the title bar of the dialog box.

•

TMA Rx and Tx Band values displayed are High and Low frequency values.

•

Minimum, Maximum and Current Gain values are same. If the TMA unit is in bypassed

mode, the current Gain would display zero value.

•

New Gain field and the button Set Gain are disabled, signifying that the Set Gain is not al

lowed.

Figure 22-2. Set Gain for Fixed Gain TMA

Disabled for Fixed Gain TMA unit.

Minimum and Maximum Gain values are
same for the Fixed Gain TMA .

6. Click

on

Close to close the dialog box to return back the Device Information list.

Advertising