Bushnell 1000 User Manual

Page 14

Advertising
background image

14

Regular Mode

(

): This mode does not provide any degree of elevation or compensated distance, but

instead, line of sight distance only.

MENU SETUP – SELECTION of BOW, RIFLE, REGULAR MODES and UNIT OF MEASURE

There are two ARC (Angle Range Compensation) modes and one REGULAR mode. The two ARC modes

are BOW mode and RIFLE mode.

To select between these modes, first turn the unit “ON” by pressing and releasing the POWER button.

Next, press and hold the MODE button for five seconds. The “SETUP” display icon will light and the

current compensation mode will be identified by either the “BOW” symbol ( ), the “RIFLE symbol

(

) lit with one of the ballistic groups (A thru J) displayed and flashing, or no indicators lit and the

message (

) flashing in the bottom of the LCD.

The modes can be cycled through in a circular fashion by pressing and releasing the mode button. The

order of modes is a follows: BOW, RIFLE A, RIFLE B, RIFLE C, RIFLE D, RIFLE E, RIFLE F, RIFLE G, RIFLE H,

RIFLE I, RIFLE J, REG, etc. When the bow selection is displayed, the “BOW” icon will flash and when

a “RIFLE: selection is displayed, the “RIFLE” icon will be steady, but the ballistic group will be flashing
toward the bottom of the LCD. When the (

) is displayed, the message (

) will flash near the

bottom of the LCD.

Once the desired distance compensation mode is displayed, select it by pressing and releasing the

POWER button. Following this selection, the current unit of measure, “Y” for yards or “M” for meters will

flash in the LCD and the SETUP icon is still lit. Pressing the MODE button will toggle the unit of measure.

When the desired unit of measure is displayed, press the POWER button to accept the unit of measure

Advertising