Models X366GGVX (X36 6 00 X) [M3Y0GTU4X(2 or 5)A]

Adapting to different types of gas

Burner Position Injector Gas Pressure

Max Rate

Min Rate

By-pass

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

diam. [mm]

Auxiliary Front

R 0,90

NG

4” 3400

996

900 264

Regulated

0,54

LP

(Propane)

11”

3400

996

900

264

0,29

Semi-Rapid

Rear L & C

1,18

NG

4”

6100

1787

1500

439

Regulated

Front

C

0,70

LP

(Propane)

11”

6100

1787

1500

439

0,36

Rapid Rear

L 1,55 NG 4”

10400

3047

2500

732

Regulated

0,92

LP

(Propane)

11”

10400

3047

2500

732

0,47

Front L Inner

0,80

NG

4”

2800

820

900

264

Regulated

Dual Burner

0,49

LP (Propane)

11”

2800

820

900

264

0,29

Front L Outer

N°2 x 1,15

NG

4”

12000

3516

4500

1318

Regulated

N°2 x 0,70

LP (Propane)

11”

12000

3516

4500

1318

0,65

Oven Oven 2,00 NG 4”

16000

4688

4000

1172

Regulated

downside

1,15

LP

(Propane)

11”

16000

4688

4000

1172

0,60

Broiler

Oven

1,90

NG

4”

14500

4248

Only Max

Only Max

No by-pass

upside

1,10

LP (Propane)

11”

14500

4248

Only Max

Only Max

No by-pass

Models X365GGVX (X36 5 00 X) [M3W0GTU4X(2 or 5)A]

Adapting to different types of gas

Burner Position Injector Gas Pressure

Max Rate

Min Rate

By-pass

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

diam. [mm]

Auxiliary Front

R 0,90

NG

4” 3400

996

900 264

Regulated

0,54

LP

(Propane)

11”

3400

996

900

264

0,29

Semi-Rapid

Rear L and R

1,18

NG

4”

6100

1787

1500

439

Regulated

0,70

LP

(Propane)

11”

6100

1787

1500

439

0,36

Rapid Rear

L 1,55 NG 4”

10400

3047

2500

732

Regulated

0,92

LP

(Propane)

11”

10400

3047

2500

732

0,47

Centre

Inner

0,80 NG 4”

2800

820

900

264

Regulated

Dual Burner

0,49

LP (Propane)

11”

2800

820

900

264

0,29

Centre Outer

N°2 x 1,15

NG

4”

12000

3516

4500

1318

Regulated

N°2 x 0,70

LP (Propane)

11”

12000

3516

4500

1318

0,65

Oven Oven 2,00 NG 4”

16000

4688

4000

1172

Regulated

downside

1,15

LP

(Propane)

11”

16000

4688

4000

1172

0,60

Broiler

Oven

1,90

NG

4”

14500

4248

Only Max

Only Max

No by-pass

upside

1,10

LP (Propane)

11”

14500

4248

Only Max

Only Max

No by-pass

CAUTION: save the orifices removed from the appliance for future use

REGULATION OF BURNERS

Primary air adjustment:

Oven burner adjustment: follow the instructions below to adjust the primary air for the over burner:
1) Remove the oven bottom.
2) Loosen the screw P and adjust the position X of the Venturi cone (Fig. 13) according to the measurements indicated in
table 4.
Broiler burner adjustment: to adjust the broiler burner loosen screw P and adjust the position X of the Venturi cone
(Fig. 14) according to the measurements indicated in table 4.


TABLE N°4: Burner primary air regulation (indicative)

Burner
Type of gas

Oven Broiler

Inches (mm)

Inches (mm)

NG (Natural Gas)

9/16 (15)

fully open

LP (Propane Gas)

fully open

fully open