Models X366GGVX (X36 6 00 X) [M3Y0GTU4X(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure
Max Rate
Min Rate
By-pass
diam. [mm.]
Type
[i.w.c.]
[BTU/h]
[W]
[BTU/h]
[W]
diam. [mm]
Auxiliary Front
R 0,90
NG
4” 3400
996
900 264
Regulated
0,54
LP
(Propane)
11”
3400
996
900
264
0,29
Semi-Rapid
Rear L & C
1,18
NG
4”
6100
1787
1500
439
Regulated
Front
C
0,70
LP
(Propane)
11”
6100
1787
1500
439
0,36
Rapid Rear
L 1,55 NG 4”
10400
3047
2500
732
Regulated
0,92
LP
(Propane)
11”
10400
3047
2500
732
0,47
Front L Inner
0,80
NG
4”
2800
820
900
264
Regulated
Dual Burner
0,49
LP (Propane)
11”
2800
820
900
264
0,29
Front L Outer
N°2 x 1,15
NG
4”
12000
3516
4500
1318
Regulated
N°2 x 0,70
LP (Propane)
11”
12000
3516
4500
1318
0,65
Oven Oven 2,00 NG 4”
16000
4688
4000
1172
Regulated
downside
1,15
LP
(Propane)
11”
16000
4688
4000
1172
0,60
Broiler
Oven
1,90
NG
4”
14500
4248
Only Max
Only Max
No by-pass
upside
1,10
LP (Propane)
11”
14500
4248
Only Max
Only Max
No by-pass
Models X365GGVX (X36 5 00 X) [M3W0GTU4X(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure
Max Rate
Min Rate
By-pass
diam. [mm.]
Type
[i.w.c.]
[BTU/h]
[W]
[BTU/h]
[W]
diam. [mm]
Auxiliary Front
R 0,90
NG
4” 3400
996
900 264
Regulated
0,54
LP
(Propane)
11”
3400
996
900
264
0,29
Semi-Rapid
Rear L and R
1,18
NG
4”
6100
1787
1500
439
Regulated
0,70
LP
(Propane)
11”
6100
1787
1500
439
0,36
Rapid Rear
L 1,55 NG 4”
10400
3047
2500
732
Regulated
0,92
LP
(Propane)
11”
10400
3047
2500
732
0,47
Centre
Inner
0,80 NG 4”
2800
820
900
264
Regulated
Dual Burner
0,49
LP (Propane)
11”
2800
820
900
264
0,29
Centre Outer
N°2 x 1,15
NG
4”
12000
3516
4500
1318
Regulated
N°2 x 0,70
LP (Propane)
11”
12000
3516
4500
1318
0,65
Oven Oven 2,00 NG 4”
16000
4688
4000
1172
Regulated
downside
1,15
LP
(Propane)
11”
16000
4688
4000
1172
0,60
Broiler
Oven
1,90
NG
4”
14500
4248
Only Max
Only Max
No by-pass
upside
1,10
LP (Propane)
11”
14500
4248
Only Max
Only Max
No by-pass
CAUTION: save the orifices removed from the appliance for future use
REGULATION OF BURNERS
Primary air adjustment:
Oven burner adjustment: follow the instructions below to adjust the primary air for the over burner:
1) Remove the oven bottom.
2) Loosen the screw P and adjust the position X of the Venturi cone (Fig. 13) according to the measurements indicated in
table 4.
Broiler burner adjustment: to adjust the broiler burner loosen screw P and adjust the position X of the Venturi cone
(Fig. 14) according to the measurements indicated in table 4.
TABLE N°4: Burner primary air regulation (indicative)
Burner
Type of gas
Oven Broiler
Inches (mm)
Inches (mm)
NG (Natural Gas)
9/16 (15)
fully open
LP (Propane Gas)
fully open
fully open