Watts CSM-91-INS User Manual

Insulation systems, For balancing and flow measurement applications, Sizes: 2

Advertising
background image

For Balancing and Flow Measurement Applications

ES-CSM-91-INS

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

Insulation Systems

Sizes: 2

1

2

" – 6" (65 – 150mm)

Watts Insulation Systems are available in sizes 2

1

/

2

" – 6"

(65 – 150mm) to suit series CSM-91 circuit balancing valves
and series TDV Triple Duty Combination Valves.
The outside shell is a preformed, removable PVC jacket to meet
ASTM D 1784/class 14253-C, MEA #7-87, ASTM-E-84 and
ASTM-136 with a flame spread rating of 50 or less. There is pro-
vided sufficient mineral fiberglass insulation to meet ASHRAE
90.1-1989 specifications in operating conditions with Maximum
Fluid Design Operating Temperature Range of 141˚F – 200˚F
(61˚C – 93˚C) and Mean Rating Temperature of 125˚F (52˚C).

Materials

Outside Shell (2): Zeston 2000 PVC
Insulation Batten: Mineral Fiberglass
Fastener (4): Stainless steel

Dimensions

CSM-91-INS

Fig. 1

Fig. 2

Fig. 3

Fig. 4

ES-CSM-91-INS 0317

© Watts Regulator Company, 1996

Printed in U.S.A.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.wattsreg.com

Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscda.com

1. Wrap fiberglass insulation around valve keeping insulation

tight around valve neck and body as shown in figs. 2 & 3.

2. Cut out insulation around pressure taps so that when diag-

nostic checks are required, plugs are visible when outside
shell is removed as shown in fig. 3.

3. Slide 2-Piece outer shell over insulation snugly and then use

fastening tacks on top and bottom to secure shell as shown
in fig. 4.

Size (DN)

Dimensions

L x W x T

A

B

Insulation Batten Size

in.

mm

in.

mm

in.

mm

in.

mm

2

1

/

2

65 20

1

/

2

521

10

254

32 x 15 x 1

1

/

2

813 x 381 x 38

3

80

20

508

11

279

37 x 15 x 1

1

/

2

940 x 381 x 38

4

100 22

1

/

2

572 12

1

/

2

318

40 x 17 x 1

1

/

2

1016 x 432 x 38

5

125

26

660

14

356

48

1

/

2

x 21 x 1

1

/

2

1232 x 533 x 38

6

150 30

1

/

2

775

16

406 51

1

/

2

x 22

1

/

2

x 1

1

/

2

1308 x 572 x 38

A

B

Installation Instructions

Advertising