FIGURE 14

APPLIANCES LOCATED IN CONFINED SPACES

ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC

NOTE: The inlet and outlet air openings shall

each have a free area of not less than
one square inch per 4,000 BTU per hour
(35 square inches per gallon per hour)
of the total input rating of all
appliances in the enclosure.

FIGURE 15

APPLIANCES LOCATED IN CONFINED SPACES

ALL AIR FROM OUTDOORS

INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC

NOTE: The inlet and outlet air openings shall

each have a free area of not less than
one square inch per 4,000 BTU per hour
(35 square inches per gallon per hour)
of the total input rating of appliances in
the enclosure.