Warning, Danger – Garden Sun Heater HSS-NG-SS Natural Gas User Manual

Page 9

Advertising
background image

8

Leak Check

WARNING

• Perform all leak tests outdoors.

• Extinguish all open flames.

• NEVER leak test when smoking.

• Do not use the heater until all connections have been leak

tested and do not leak.

Hose / Regulator

Connection

Make 2-3 oz. of leak check solution (one part liquid

dishwashing detergent and three parts water).

Apply several drops of solution where hose attaches
to regulator.

Apply several drops of solution where regulator

connects to Natural gas Valve.

Make sure all Patio Heater & Light valves are OFF.

Turn Natural gas Valve ON.

If bubbles appear at any connection, there is a leak.

Turn Natural gas Valve OFF.

If leak is at Hose/Regulator connection: tighten

connection and perform another leak test. If bubbles
continue appearing should be returned to Hose’s place
of purchase.

If leak is at Regulator/Natural gas Valve connection:

disconnect, reconnect, and perform another leak

check. If you continue to see bubbles after several

attempts, Natural gas Valve is defective and should be

returned to cylinder’s place of purchase.

If

NO

bubbles

appear

at

any

connection,

the

connections are secure.

.

Turn Natural gas Valve OFF.

NOTE: Whenever gas connections are loosened or

removed, you must perform a complete leak test.

.

Complete installation.

Operation

DANGER

• CARBON MONOXIDE HAZARD

• For outdoor use only. Never use inside house, or other

unventilated or enclosed areas. This heater consumes air

(oxygen). Do not use in unventilated or enclosed areas to

avoid endangering your life.

Caution: Do not attempt to operate until you have read

& understand all General Safety Information in this

manual and all assembly is complete & leak checks

have been performed.

The appliance must be isolated from the gas supply

piping system by closing its individual manual shoutoff

valve during any pressure testing of the gas supply

piping system at test pressures equal to or less than

1/2 psig (3.5kPa).

Advertising