Step 7 – Attach Reflector Assembly to Studs

.

Support Heater.

.

Slide 3 Large Flat Washers over threaded end of

Studs.

.

Locate Reflector Assembly on 3 studs.

.

Install large flat washers on studs & securely tighten

wing nuts but do not over-tighten!

Step 8 – Connect Hose & Regulator to Cylinder

The pressure regulator and hose assembly supplied with the
appliance must be used.

The installation must conform with local codes, or in the absence
of local codes,with National Fuel Gas Code, ANSI Z223.1/NFPA54,
Natural Gas and Propane Installation Code, CSA B149.1, or Propane
Storage and Handling Code, B149.2.

A dented, rusted or damaged propane cylinder may be hazardous
and should be checked by your cylinder supplier. Never use a
propane cylinder with a damaged valve connection.

The propane cylinder must be constructed and marked in
accordance with the specifications for LP gas cylinders of the
U.S. Department of Transportation (DOT).
or the Standard for Cylinders, Spheres and Tubes for
Transportation of Dangerous Goods and Commission,
CAN/CSA-B339.

Never connect an unregulated propane cylinder to the heater.

Lift Cylinder Housing.

Screw regulator onto gas hose. Do not cross-thread.

Tighten securely.

Attach regulator to cylinder.

Complete attachment.

Install cylinder.

6 Req’d Large Flat Washers

3 Req’d Wing Nuts

The minimum permissible gas supply pressure of 10 W.C.
is required for purpose of input adjustment.
The minimum hourly of 17000 Btu is required input rating for a
heater for automatic operation at ratings less than full input rating.

You must provide propane gas and propane cylinder .
Use a standard 20 lb. propane
cylinder only.

Use this heater only with a
propane vapor withdrawal
supply system.See
Chapter 5 of the Standard
for Storage and Handling
of Liquefied Petroleum
Gas, ANSI/NFPA 58.Your
local library or fire
department should have

this book.

A minimum supply pressure
of 0.4 p.s.i. is required for
the purpose of input
adjustment for propane
gas.Storage of an appliance indoors is permissible only
if the cylinder is disconnected and removed from the
appliance. A cylinder must be stored outdoors in a
well-ventilated area out of the reach of children. A
disconnected cylinder must have dust caps tightly
installed and must not be stored in a building, garage
or any other enclosed area.

Standard 20 lb. tank

Provided with a cylinder connection device compatible with the
connection for the appliance.

Provided with a listed overfilling prevention device.

The cylinder used must include a collar to protect the cylinder valve.

(a) Do not store a spare LP-gas cylinder under or near this appliance;
(b) Never fill the cylinder beyond 80 percent full;
(c) “Place the dust cap on the cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust cape on the
cylinder valve that provided with the cylinder valve. Other type of
caps or plugs may result in leakage of propane.”