Burnham RSA User Manual
Page 33

33
Figure 25: Electrode / Head Setting for
Beckett Burner
Figure 25A: Electrode / Head Setting for
Carlin EZ-HP Burner
Table 7A: Becket AFG Burner
Table 7: Beckett AFG, AF, & SF Burners
Table 7B: Carlin EZ-2HP Burner
Boiler Model
Firing Rate
Manufacturer
GPH
Angle
Type
Head Bar
Air Band Setting
RSA85
.85
Delavan
.75
60°
A
.75
.60
RSAH85
.75
.65
W
.60/.65
.50
RSA110
1.10
.90
.85/1.00
.75
RSAH110
1.00
.85
.60
RSA125
1.25
1.10
A
1.10/1.25
.90
RSAH125
1.10
.90
.85/1.00
.65
RSA135
1.35
1.20
W
1.10/1.25
.85
RSAH135
1.25
1.10
A
.85
Boiler Model
Firing Rate
(GPH)
Hago Nozzle
Air
Settings
Shutter
Band
Head
(stop screw)
Pump Pressure
RSAH85
.75
.65 x 80B
6
0
N/A
140
RSAH110
1.0
.85 x 80B
7
RSAH125
1.1
.90 x 80B
7
RSAH135
1.25
1.0 x 80B
9
Boiler Model
Firing Rate
(GPH)
Hago Nozzle
Air
Settings
Shutter
Band
Head (stop screw)
Pump Pressure
RSA85*
.85
.75 x 80B
10
0
N/A
140
RSA110
1.10
.90 x 80B
8
RSA125
1.25
1.0 x 80B
7
RSA135
1.35
1.10 x 80B
9
RSA170
1.70
1.65 x 80A
7
100
RSA195
1.95
2.00 x 80B
7
RSA240
2.40
2.50 x 80B
7
RSA285
2.85
3.00 x 80B
7
* Equipped with low firing rate baffle