Settings for HK AUDIO VX 2400 amps:
Gain VX 2400: + 35 dBu
Max Output ( Firnet): + 6 dBu
The FIRNET’s limiter cannot effectively attenuate
signals when set to other dBu levels, so connected
speakers may be damaged or destroyed.

7.4.5.5

Muting Outputs

The SPEAKER, SCENE, LEVEL, DELAY/PHASE and
ADMIN keys serve the second purpose of muting
outputs. The label above each key tells you its
mute function. To mute outputs, press and hold
the MUTE/HOLD key and press the key of the
output you wish to mute (key A to D for Output
A to Output D). The Lim/Mute LED in the given
output’s LED chain lights up red to indicate the
output is muted. Follow the same procedure to
enable the output.

7.5 Firmware

The FIRNET controller ships with the current
fi rmware. LIPAN software lets you update the
device with future fi rmware versions. See chapter 4
LIPAN PC Software, to learn more about fi rmware
updates.

8 Technical Data

Connectors

Analog Input

3-pin XLR female

Pin assignments

1 = ground, 2 = signal (+), 3 = signal (-)

Input impedance

9 k-ohms

Maximum input level

Variable; 6, 12, 18, and 24 dBu

Dynamic range, input

> 128 dB (A)

Digital input

3-pin XLR female

Pin assignments

1 = ground, 2 = signal, 3 = signal

Input impedance

110 ohms

Protocol

AES 3 (AES/EBU)

Clock rate

48 or 96 kHz, and 96 kHz internal

Synchronization

To an external source (slave mode)

Digital output

3-pin XLR male

Pin assignments

1 = ground, 2 = signal, 3 = signal

Output impedance

110 ohms

Protocol

AES 3 (AES/EBU)

Signal processing

Refresh signal form and level

(Bypass at power failure)

Analog outputs

3-pin XLR male

Pin assignments

1 = ground, 2 = signal (+), 3 = signal (-)

Output impedance

35 ohms

Maximum output level

Variable; 6, 12, 18, and 24 dBu

Dynamic range, output

> 125 dB (A)

Mains voltage connector

Three-pole non-heating equipment connector

Mains voltage / frequency

100 to 240 V / 50 - 60 Hz

Power consumption

40 VA

Max. curr. cons. at 100 V mains volt.

400 mA

Max. curr. cons. at 230 V mains volt.

175 mA

Ethernet X port

RJ-45, RJ-45, cross-connected

Ethernet II port

RJ-45, RJ-45, direct-connected

Audio data

(Linear Through mode)

Frequency response (-1 dB)

5.5 Hz to 34 KHz

THD+N (20 Hz to 20 kHz)

AD>DA input level 21dBu,

R=100k, 96 kHz 0.0012%-0.0013%

AES>DA input level -3dBFS,

R=100k, 96 kHz 0.0010% - 0.0012%

Latency (incl. limiter):

AD > DA 96 KHz 3.15ms

AD > AES/EBU 96 KHz

AES/EBU > A 96 KHz

+ FIR fi lter (Cohedra / Coh. Compact)

5.8 ms

Digital signal processing

Internal sampling rate

96 kHz

Internal data format

32-bit fl oating point

AD converter resolution

28 bits

DA converter resolution

24 bits

Operating conditions

Temperature range

-10° C to +70°C

Hardware specifications

Weight

6.6 lbs. • 3 kg

Measurements (D x H x W)

48 x 4.4 x 23.2 cm

18-7/8 x 17-5/16 x 9-1/8"