Other Fixture Mounting Options

The grommet holes along

the edge of the fixture are

designed to allow the fixture

to be screwed onto set walls.

Ballast Operation

WARNING!

1) ALWAYS TURN OFF THE BALLAST BEFORE connecting or

disconnecting Lamps, Harnesses or Extension Cables.

2) Use only with Sine wave inverters. Do not operate on SCR dimmers.

3) If powering the ballasts through a Dimmer Pack, set the Dimmer to

Non-Dim mode.

The Ballast requires 100-240VAC 50/60 Hertz on an earth grounded circuit;

The electronic Ballast operates at a high frequency of 25kHz. It is

dead-quiet, instant-on and lightweight.

Cold Temperature Operation

The Ballast is designed to operate at temperatures from 14°F to 122°F

(-10°C to +50°C). In cold temperatures, the Ballast may not strike the

lamp(s) instantly. Switch the Ballast to OFF, wait seven seconds and

try again. If the Ballast does not strike after two or three attempts, turn off

the Ballast, check that the Extension and Harness connections are secure

and re-strike. Once operating for a few minutes, the lamps should re-strike

instantly.