The Image 82 Fixture is used for example purposes throughout these
instructions.

A

B








A ) Power Switch: Has a built-in indicator light, which can detect if
AC power is present in power cord. "O" = OFF position

B ) Fuse: Provides circuit protection.
Note: If Fuse is blown or open replace with same type of fuse rating
as marked.


















Provide 120 Volt AC primary power.
Do not dim the fixture through a dimming circuit.
If powering the fixtures through a dimmer board, set the
dimmer profile to non-dim.

Load Considerations:

Kino Flo ballasts are not power factor corrected. They will draw
double the current on the neutral from what is being drawn on
the two hot legs. On large installations it may be necessary to
double your neutral run so as not to exceed your cable
capacity.