Klimaire CSM42H2P16 User Manual

Page 12

Advertising
background image

12

1/2” bolt

5/16” bolts

Fig. 9 COVER AND FAN

3.10 REMOVING THE TOP PANEL AND MOTOR

When motor requires changing follow the steps below:
Step 1: Go into electrical panel, disconnect motor power lines.
IMPORTANT NOTE
Disconnect main power to unit. Severe burns and electrical shock will occur if
you do not disconnect main power.
Step 2: Remove cover (be careful of motor wires)
Step 3: Be sure to place fan cover unit on the ground as indicated in Fig. 9
IMPROTANT NOTE
Do not place or lean fan blades on ground or against surface.
Step 4: Remove fan motor by removing 5/16” bolts from cover.
Step 5: Remove fan blade from motor by removing 1/2” bolt and place fan on the ground.
Step 6: Reverse removal process to reinstall the fan and motor.
IMPROTANT NOTE
When connecting motor wires be sure to check motor direction.

Damage will occur to condenser unit
if you remove fan bolts prior to cover removal.

NOTE:

REQUIRED PARTS LIST

SEE DETAIL B

#7 X 3/8” Self Tapping Screws
(Don’t Exceed 3/8” long)

1/4” Χ 1-1/2” Hex Washer Head Concrete Screws
(3/16” Pilot Hole Needed. Pilot Hole Should Be1/4” Deeper
Than The Fastener Embedment)

Fig.8 FACTORY-PREFERRED TIE-DOWN METHOD

DETAIL B

Brackets:
2” width, 1/16” thickness,
height as required.
Available from distributor
or in market place.

The dimension see FIG.2