Energy saver, Operating characteristics, Dimensions and capacities – Bock Water heaters Electric Water Heaters User Manual

Page 2

Advertising
background image

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491

Phone 608.257.2225

Fax 608.257.5304

80031 Rev 3/08

Dielectric Fittings: Factory Installed

T&P Valve: Factory Installed

Brass Drain Valve: Factory Installed

Relief Valve Opening: 3/4”

Hand-hole Cleanout Opening: Standard

Pressures (all): Working Pressure, 150 psi;

Testing Pressure, 300 psi

Warning: Do not install on combustible flooring.

Installation should be in accordance with all

national and/or local codes. In the absence of

local codes, refer to NFPA 31, NFPA 54 or ANSI

Z.21.10.1.

Caution: The recommended maximum hot water

termperature setting for normal residential use is

120°F. Bock recommends a tempering valve or

anti-scald valve be installed and used according to

the manufacturer’s directions to prevent scalding.

Energy Saver

120

80

50

Dimensions and Capacities

Model

Storage

(gal)

kW

Input

Inlet

Pipe

Dia.

Dimensions

Shipping Weight

(lbs)

A

B

C

D

E

Standard

ASME

50F-*

50

**

1-1/2

24

47-3/4

46-1/2

49-1/4

41

270

302

80F-*

80

**

1-1/2

26

60-1/4

46-1/2

61-3/4

52-1/2

335

378

120F-*

119

**

1-1/2

30-1/4

64-1/2

50-1/4

66

55

430

485

*When order surface mounted thermostat, add the letter “S” before the “F”. Example 50SF

*When ordering the Immersion thermostat add the letter “C” before the “F”. Exampe 50CF

*For ASME construction add an “A” to the model number. Example 50CF-A

**Add a “6”, “9”, “12”, “13.5”, “15”, “18”, “24”, “27”, “30”, “36”, “45”, or “54” to the model number to indicate kW

input desired. Example 50S(C)F-6

Where Applicable

Operating Characteristics

Recovery

@

Full Load Current Amperes (Fused Models)***

kW

Input

208 Volts

Phase

240 Volts

Phase

277

Volts

Phase

380

Volts

Phase

415

Volts

Phase

480 Volts

Phase

600

Volts

Phase

90°F

Rise

100°F

Rise

1

3

1

3

1

3

3

1

3

3

6

28

25

28.8

16.6

25

14.4

21.6

10

9

12.5

7.2

5.8

9

42

37

43.2

25

37.2

21.6

32.4

14

13

18.7

10.8

8.7

12

55

50

57.6

33.3

50

28.9

43.3

19

17

25

14.4

11.5

13.5

62

56

64.9

37.5

56.2

32.5

48.7

21

19

28.1

16.2

13

15

69

62

72.1

41.6

62.5

36.1

54.1

23

21

31.2

18

14.4

18

83

74

86.5

50

75

43.4

64

28

25

37.5

21.6

17.3

24

110

99

115.4

66.7

100

57.8

86.6

37

34

50

28.9

23.1

27

124

112

129.8

75

112.5

65

97.4

41

38

56.2

32.5

26

30

138

124

144.2

83.3

125

72.2

108.3

46

42

62.5

36.1

28.9

36

165

149

173

100

150

86.7

129.9

55

50

75

43.3

34.6

45

207

186

216.3

125

187.5

108.3

162.4

69

63

93.7

54.1

43.3

54

248

223

259.6

150

225

130

194.9

83

75

112.5

65

52

Number of Elements (Fused Models)***

kW

Input

208 Volts

Phase

240 Volts

Phase

277

Volts

Phase

380

Volts

Phase

415

Volts

Phase

480 Volts

Phase

600

Volts

Phase

1

3

1

3

1

3

3

1

3

3

6

3(2)

3

3(2)

3

3

3

3

3(2)

3

3

9

3

3

3

3

3

3

3

3

3

3

12

3

3

3(2)

3

3

3

3

3(2)

3

3

13.5

3

3

3

3

3

3

3

3

3

3

15

3

3

3

3

3

3

3

3

3

3

18

3

3

3

3

3

3

3

3

3

3

24

4

6

4

6

4

6

6

4

6

6

27

6

6

6

6

6

6

6

6

6

6

30

6

6

6

6

6

6

6

6

6

6

36

6

6

6

6

6

6

6

6

6

6

45

9

9

9

9

9

9

9

9

9

9

54

9

9

9

9

9

9

9

9

9

9

Units with amperage draw of 48 amps or more require factory installed internal fusing.

***If the number of elements on non-fused models is different, it is indicated in parentheses (), following the AMP draw.