Powers e420 Series Combination T/P Tempering Valves - Thin Wall Mounting Kit User Manual

Installation instructions

Advertising
background image

INSTALLATION INSTRUCTIONS

THIN WALL MOUNTING KIT (#800-100) FOR SERIES 410

AND 420 HYDROGUARD MIXING VALVES

A Watts Industries Co.

1.

If possible, mount thin wall mounting bracket before wall is in place; proceed to Step 2. If wall is already in place, cut
rough-in hole using the dimensions in Figure 3 for Series 410 or Figure 4 for the Series 420 valves (see reverse side).

2.

Place the thin wall mounting bracket over the bonnet of the valve as in Figure 1. When working with the Series 410 and 420
valves, make sure the words "FRONT TOP 410-420" are visible on the mounting bracket.

3.

Rotate the bracket so that the words are right side up. The top hole should expose the stop adjustment screw (for the 410
valve only) and the two side holes of the bracket should expose the
mounting holes for the dial plate (see Figure 2).

4. Complete the installation of the valve trim. Follow the appropriate

installation instruction, which is packaged with the mixer:

410 Hydroguard – Form TI410

420 Hydroguard – Form TI420

INSTALLATION INSTRUCTIONS

Figure 1

Figure 2

Form 129-075

Form 129-075 0218

EDP# 6512208

Printed in U.S.A.

USA office: Phone: 800.669.5430 • Fax: 847.824.0627

www.powerscontrols.com

Canadian office: Phone: 888.208.8927 • Fax: 888.882.1979

© 2002 Powers, a Watts Industries Co.

A Watts Industries Co.

Advertising