Series MPB,

close-coupled design

Page 4

9240-050-en

Revision 05

TM 7345

Edition 10/2008

Pipe screws, DIN/ISO flanges drilled to ASME

DN

No. x size

Tightening torque

[mm] [inch]

[ASME]

[Nm]

[in-lbs]

25

1“

4 x ½“

8

70

1.2 Type plate, dry-running, CE

and housing markings

The stainless steel type plate is firmly riveted to the
lantern:
If the operator attaches his identification, it must be
ensured that the pump matches the application in
question.
Example of type plate:

Dry-running:

CE marking:
(only for pumps to ATEX 95)

Housing identification:
The following are visible on the housing according to
DIN EN 19:

Nominal size
Rated pressure
Housing material
Manufacturer's identification
Melt number/Foundry identification
Foundry date

2

Notes on safety

This operating manual contains fundamental
information which is to be observed during installation,
operation and maintenance.
It must be read before installation and
commissioning!
This operating manual must always be available at the
place of use of the machine/plant.
In addition to the general notes on safety under the
main heading “Safety”, special notes on safety are
included at other points and must be observed.
Installation, operation and maintenance are to be
performed by qualified staff.
The area of responsibility, authority and supervision of
the staff must be exactly regulated by the customer.
If the staff do not have the necessary expertise, they
are to be trained and instructed.
If necessary, this can be provided by the
manufacturer/supplier on behalf of the machine
operator.

General hazard symbol! People may be put
at risk.

Safety symbol! The pump and its function
may be put at risk if this safety symbol is not
observed.

EU marking! Explosion-protected equipment
must be identified for work in potentially
explosive areas.

Warning of a magnetic field!

Warning of electric power!

This warning sign must be used if people
with a pacemaker are at risk, e.g. from a
strong magnetic field.

It is imperative to observe signs attached directly to
the pump / unit, e.g.:

Direction of rotation arrow
Warning against dry-running

and they are to be kept legible.
Non-observance of the notes on safety may result
in the loss of any and all claims for damages.
Non-observance may involve the following hazards :

Failure of important functions of the machine/plant.
Failure of electronic equipment and measuring
instruments due to magnetic fields.