Safety, transport and storage
The relevant sections in the adjacent installation and 
operating manuals apply to safety, transport and 
storage. 
This installation and operating manual is only valid in 
conjunction with the installation and operating 
manuals of 
SCK long-life grease and oil bath lubrication 
9220-050-en
2.1 Intended use
Double mechanical seals for plastic-lined pumps of 
the series SCK are suitable for the use of aggressive, 
toxic, pure and inflammable media. 
The instructions contained in the operating 
manual or contractual documentation are to be 
observed, if necessary consult the manufacturer. 
All the important features are documented in the data 
sheet included in the scope of delivery. 
 
3
Product description
For a product description of the pump, see the 
installation and operating manual for the SCK series. 
The sectional drawing shows a stationary, double 
mechanical seal RG-5, with quench or liquid sealed. 
See Section 7
All components which come into contact with the 
process medium are either lined with plastic or are 
made of other resistant materials, e.g. silicon carbide. 
 
4
Commissioning / Shutdown
4.1 Initial commissioning
See installation and operating manual for the series 
SCK. 
 
4.2 Mechanical seals
The design and material combination are specified in 
the data sheet. 
The proper condition of the components and 
the protective facilities must be ensured to 
prevent any risk from escaping medium. 
The regulations and recommendations of the 
mechanical seal manufacturer must always be 
observed. 
 
4.2.1 Use in an explosive area
Use in an explosive area means that only 
mechanical seals may be employed which 
permit observation of temperature. 
The operating manual of the respective mechanical 
seal manufacturer is an integral part of this general 
operating manual. 
This permits, amongst other things, the calculation of 
the expected surface temperature at the mechanical 
seal. The suitability for the permissible temperature 
class as per ATEX is hereby given. 
CAUTION:
The permissible temperature class of the complete 
unit (pump, mechanical seal, coupling, motor) is 
determined by the lowest temperature class of the 
individual components. 
Example: Pump T4, mechanical seal T3,
coupling T4, motor T4
In both cases the unit may only be used in 
atmospheres which may ignite above the temperature 
class T3, i.e. >200 °C (>392°F). 
 
4.2.2 Mechanical Seal RG-5, with quench
The design and material combination are specified in 
the data sheet. 
A pump with a stationary mechanical seal with 
quench may only be started up when the quench 
system is in operation and the pump is filled with 
process medium. 
The pressure of the quench fluid must be max. 1 bar. 
The admissible pressure for the storage container 
must also be observed. 
If process water is used for quenching, a flow rate of 
approx. 40 l/h should be set. After a running-in phase 
of approx. 10 h the flow rate can be reduced so that 
the quench fluid emerges heated by about 20°C. A 
minimum flow rate of 5 l/h should be maintained. 
Are the available connections correctly made?
QE - quench fluid inlet 
QA - quench fluid outlet 
See also sectional drawing in Section 7.