3 notes on assembly, 6 faults, Shaft sleeve – Richter Mechanical Seals User Manual

Page 5: Notes on assembly, Assembly fehler! textmarke nicht definiert, 6faults, Series sck

Advertising
background image

Series SCK

, mechanical seals with quench

Page 5

9220-012-de

Revision 01

TM 6478

Edition 04/2006

5.2 RG-4

with

lip

ring

dismantling / assembly
shaft sleeve

Pull the shaft sleeve 524 off the shaft.
Remove sealing house 483 with lip ring 413/2.
Assemble new lip ring 413/2 in the sealing house
483. Assemble carefully! The lip ring could be
damaged.
Attach the assembly cone for the assembly of lip
ring 413/2 and shaft sleeve. 524. See Picture 1.
For assembly aid for assembly cone, see Section
10.3
in the installation and operating manual SCK.
Push shaft sleeve with lip ring onto the shaft.

Picture 1

5.3 Notes on assembly

Only use original spare parts.
Do not use any defective parts.
During assembly the accepted rules of mechanical
engineering are to be observed.
Bearing pedestal group 3:
Always make sure that during installation of the
mechanical seal the labyrinth disc is secured by 2
bolts.
The bolts must be removed again after installation
of the impeller.
The rotary ring carrier 485/1 must engage in the
spring-type slotted pin 531/1. Mark position
beforehand.
The seal face 472/2 must engage in the studs
560/1. Mark position beforehand.
The rotating unit 470/1 must be flush with the key
940/2 in the case of a shaft sleeve made of Al

2

O

3

and tightened with the setscrew 904/2. In the case
of a shaft sleeve made of stainless steel the key is
positioned firmly against one end.
When pushing on the mating ring 475/1, make
sure that the position of the flat section matches
that on the shaft.

6

Faults

Faults may result from inadmissible modes of
operation. Such inadmissible modes of
operation – even brief ones – may cause

serious damage to the unit.
In connection with explosion protection, potential
sources of ignition (overheating, electrostatic and
induced charges, mechanical and electric sparks) can
result from these inadmissible modes of operation;
their occurrence can only be prevented by adhering to
the intended use.

Should there be any uncertainty about the remedy to
be applied, please inquire at the in-house pump office
or at the pump manufacturer's.
See also Section 8 in the installation and operating
manual of the SCK series.