6 faults, 7 sectional drawing, 1 legend – Richter Mechanical Seals User Manual

Page 8: Single mechanical seal with lip seal and quench, Dismantling, Assembly, 6faults, Series sck

Advertising
background image

Series SCK,

mechanical seal, external, single

Page 8

single with double lip seal on the wetted side

single with lip seal on the atmosphere side, with quench

9220-060-en Revision 10
TM 7827

Edition 03/2010

6

Faults

Faults may result from inadmissible modes of
operation. Such inadmissible modes of
operation – even brief ones – may cause

serious damage to the unit.
In connection with explosion protection, potential
sources of ignition (overheating, electrostatic and
induced charges, mechanical and electric sparks) can
result from these inadmissible modes of operation;
their occurrence can only be prevented by adhering to
the intended use.

Should there be any uncertainty about the remedy to
be applied, please inquire at the in-house pump office
or at the pump manufacturer's.
See also Section 8 in the installation and operating
manual of the SCK series.

7

Sectional drawing

7.1 Legend

161

back plate

210

shaft

400/x

flat gasket

412/12

o-ring

413/x

lip seal

470/2

rotating unit

475/1

mating ring

483

seal housing

487

mating ring adapter

506

retaining ring

509/2

intermediate ring

524

shaft sleeve

543

distance bush

554/3

washer

554/7

washer

*(only bearing pedestal group 0, 2, 3)

685

seal guard

710

tube

901/7

hex. screw

*(only bearing pedestal group 0, 2, 3)

902/3

stud

904/1

setscrew

917/3

screw-in pipe connector

919/1

countersunk screw

**(only bearing pedestal group 1)

920/3

hex. nut

Advertising