5 notes on dismantling, 1 protective clothing, 2 magnetic fields – Richter MNKA Series (ASME) User Manual

Page 17: 6 dismantling, 1 removing the bearing pedestal, Notes on dismantling, Protective clothing, Magnetic fields, Dismantling, Removing the bearing pedestal

Advertising
background image

Series MNKA,

acc. to ASME

Page 17

9250-050-en

Revision 11

TM 7903

Edition 07/2010

7.5 Notes on dismantling

All repair and maintenance work is to be performed
by skilled staff using appropriate tools and original
spare parts.
Is the necessary

documentation

available?

Has the pump been taken out of operation,
evacuated and flushed correctly? See also

Section 6.3.

If no new assembly is performed immediately after
dismantling, the plastic and ceramic components in
particular must be stored carefully.

7.5.1 Protective clothing

Even if the pump has been properly
evacuated and flushed, residue of the
medium may still remain in the pump, e.g.

between sealing surfaces or in the bearing seats or in
the can (containment shell) or the can (containment
shell) insert.
Plastic components may absorb medium which
gradually emerges from the material after flushing.

Proper protective clothing is to be worn.

Protective clothing is also to be worn even if only the
bearing pedestal is to be removed. Medium may have
penetrated the lantern chamber through the can
(containment shell).

7.5.2 Magnetic fields

Caution ! Strong magnetic fields !

Risk during dismantling and in the vicinity of
magnetic drives as single parts.

Remove loose parts and other magnetisable metals
from the work bench. They could otherwise be
attracted: Risk of accident!
Place any tools needed at a safe distance.
Keep

electronic

equipment

and

measuring

instruments at a distance. In cases of doubt consult
the equipment manufacturer.
Hold magnetic drives as single parts firmly or secure.
Otherwise they could be attracted, for example, by a
vice: Risk of accident!

People with an artificial pacemaker:
Keep torso

at a minimum distance of

20” (500 mm)

.

Mechanical watches as well as electronic data carriers
and digital watches or pocket calculators:

6” (150 mm) distance.

Data carriers such as credit cards, cheque cards, ID
cards with magnetic strips or magnetic tape:

6” (150 mm) distance

.

7.6 Dismantling

There are 3 possibilities for dismantling:

1. Remove the complete pump from the plant.
2. Remove the complete slide-in unit, i.e. the housing

(casing) remains in the plant.

If the coupling is a spacer-type coupling, the
motor can also remain in the plant.

3. Only remove the drive section, i.e. the pump does

not need to be drained (back pull-out design).

See

Section 5.8

.

The dismantling dimension is 3,78" (96 mm) for group
1 and 5,12" (130 mm) for group 2. See drawing 9220-
00-3006.
Dismantling of the complete pump is described.

Undo the support bracket

183

from the base plate.

The bearing pedestal

330

and support bracket are

one part in bearing pedestal group 1. In bearing
pedestal group 2 the support bracket

183

is

secured with 2 hex. screws

901/2

and tooth lock

washers

936/2

to the bearing pedestal

330

.

Undo housing (casing) screws

901/3

.

Remove housing (casing)

100

.

If the housing (casing)

100

remains in the plant, leave

the housing (casing) gasket

401

in the centering to

protect the housing (casing) sealing surface.

7.6.1 Removing the bearing pedestal

Caution !

Magnetic forces !

Risk of accident !

High magnetic forces can trap fingers and personal
injury.

Axial forces

are produced when the bearing pedestal

330

is pulled out of the lantern

344.

They diminish

again abruptly after it has been pulled out.
The torque of the magnetic drive installed is indicated
on the

name plate

.

Undo screws

901/4

of the lantern/bearing pedestal.

Separate bearing pedestal

330

from the lantern

344

using the jacking screws

908/1

.

Remove flat gasket

400/1

.

7.6.2 Dismantling the bearing pedestal,

long life grease lubrication

Clamp the end of the drive shaft

213

in a vice. Use

protective jaws.
Undo hex. socket screw

914/1

counterclockwise.

Pull off drive magnet assembly

858

.

Remove pump from the vice.
Undo rear bearing cover

361

.

Remove wavy spring washer

953/1

.

Pull out drive shaft

213

with the two radial ball

bearings

321

.

Advertising