6 fill bearing pedestal with oil, 9 tests, Fill bearing pedestal with oil – Richter MNK Series User Manual

Page 21: Tests

Advertising
background image

Series MNK 200-150-315

Page

21

9230-053-en

Revision 12

TM 8195

Edition 03/2011

When tightening the housing screws 901/3, make
sure that the support bracket 183 is firmly
positioned. If necessary, undo support bracket,
align and secure again.
For tightening torques, see Section 1.1.

The distances X and Z are given in the works
certificate. See sectional drawing in Section 10.1.
The dimensions "X" and "Y" are always to be
checked with the rotating unit against the suction
nozzle.
X: Distance behind the impeller

= 2,9 bis 3,7 mm

Y: Distance in front of the impeller = 2,5 bis 3,5 mm
These distances must be observed. The dimension Y
can be affected by the thickness of the housing
gasket.

7.8.6 Fill bearing pedestal with oil

Oil quantities:

For group 4 approx. 3000 ml
Type of oil:
See Section 7.2.2.
Procedure for filling with oil:

Tilt constant level oiler 638/1.
Fill the oiler with oil.
Swing the constant level oiler into the vertical

position.

If the oil level still falls too much, pour more oil into

the oiler.

Fig. 7

7.9 Tests

The pumps are tested with water at the
manufacturer's.
The operating data measured are documented in a
works certificate.
If, during a test after repairs, discrepancies compared
with the works certificate are discovered, the following
people can be called in:
1) in-house pump office
2) The manufacturer Richter

or its local agent

The following conveying data can be checked using
the pump performance curves:

Flow rate
Head
Power requirement
NPSHR

Advertising