5 transport, storage and disposal, Clean air act (ta luft), 5transport, storage and disposal – Richter TSG/F Series Sight Glasses User Manual

Page 7: Series psg/f, tsg/f

Advertising
background image

Series PSG/F, TSG/F

Page 7

9540-050-en

Revision 02

TM 7476

Edition 03/2009

1. Chargeable liquid and non-conductive

lining

Charges can occur on the lining surface. As long
as the valve is completely filled with medium, no
hazardous discharges can result from these
charges.
As a result, this can produce discharges inside the
valve. However, these discharges cannot cause
ignitions if the valve is completely filled with
medium.
If the valve is not completely filled with medium,
e.g. during evacuation and filling, the formation of
an explosive atmosphere must be prevented, e.g.
by superimposing a layer of nitrogen. It is
recommended to wait 1 hour before removing the
valve from the plant in order to permit the
elimination of static peak charges.
This means that, to safely prevent ignitions, the
valve must be completely filled with medium at all
times or else a potentially explosive atmosphere
must be excluded by superimposing a layer of inert
gas.

2. Chargeable liquid and conductive lining

No hazardous charges can occur as charges are
discharged direct via the lining and shell (surface
resistance

< 10

9

Ohm, leakage resistance

< 10

6

Ohm)

Static discharges of non-conductive linings are
only produced through the interaction with a
non-conductive medium and are therefore the
responsibility of the plant operator.
Static discharges are not sources of ignition
which stem from the valves themselves!
The temperature of the medium must not exceed
the temperature of the corresponding temperature
class or the maximum admissible medium
temperature as per the operating manual.
If the valve is heated (e.g. heating jacket), it must
be ensured that the temperature classes
prescribed in the Annex are observed.
To achieve safe and reliable operation, it must be
ensured in inspections at regular intervals that the
valve is properly serviced and kept in technically
perfect order.
Increased wear to the valve can be expected with
the conveyance of liquids containing abrasive
constituents. The inspection intervals are to be
reduced compared with the usual times.
Actuators and electric peripherals, such as
temperature, pressure and flow sensors etc., must
comply with the valid safety requirements and
explosion protection provisions.
The valve must be grounded.
This can be achieved in the simplest way via the
pipe screws using tooth lock washers.
Otherwise grounding must be ensured by other
action, e.g. cable bridges.
Plastic-lined valves must not be operated with
carbon disulphide.

4

Safety note for valves, certified to Clean Air Act (TA Luft)

On request, this valve can be supplied compliant with
the German Clean Air Code.
Certificate / Manufacturer Declaration Validity is
dependent on the operating instructions being read
and observed.

In particular, servicing must be conducted at regular
intervals, and the bolted connections relevant for
tightness must be inspected and retightened if
necessary.

5

Transport, storage and disposal

It is imperative, for all transport work, to
observe generally accepted engineering
practice and the accident prevention

regulations.

The valve is supplied with flange caps. Do not
remove them until just before installation.
They protect the plastic surfaces against dirt
and mechanical damage.

Handle the goods being transported with care. During
transport the valve must be protected against impacts
and collisions.
Directly after receipt of the goods, the consignment
must be checked for completeness and any in-transit
damage.
Do not damage paint protection.