9.7 Tests

Following the assembly of the valve, the stroke and
the test pressure must be checked.

9.7.1 Stroke

Lift check:

The measurement can be made with a slide calliper
gauge and a depth indicator to DIN 862.

The lift is derived from the difference in the two
heights. It must be at least as high as the lift given in
the test certificate.

9.7.2 Test pressure

This test should take place on a test bench with a
neutral medium such water. Regarding their suitability
and precision, the pressure gauges must conform to
the requirements of current national regulations (in
Germany: e.g. VdTÜV data sheet "Safety Valve 100"
of the Association of the German Technical Supervi-
sory Boards).

All pressure tests should be carried out in
compliance with DIN EN 12266-1 or API 527.

It is recommended to perform a bubble test with a
5 mm diameter hose positioned 5 mm below the
surface of water. The other end of the hose is
sealed to the outlet of the valve by means of a
stopper.

To check the test pressure, the pressure in the
valve inlet is slowly increased until the valve com-
mences to open.

To check the reseating pressure, the pressure in
the valve inlet is slowly decreased until the valve is
bubble-tight.

10 Drawings

10.1 Legend

100

body

105

cover flange

204

plug

205

seat

206

bellows

207

cap

307/1

guide bush

308

insert sleeve

400/1

O-ring

509/1

groove nut

537

lower spring plate

581

straining screw

800

valve stem

901/1

hex. screw

920/1

hex. nut

935/1

lead seal

936/x

tooth lock washer

939/x

spring-type pin

952/1

pressure spring

Advertising