2 notes on safety, 1 intended use, 2 for the customer / operator – Richter KNARP-S/F Series Control Ball Valves User Manual

Page 7: 3 improper operation, Intended use, For the customer / operator, Improper operation, Series series knar/f, knarp/f, knar-d/f, knarp-d/f, Knar-s/f, knarp-s/f

Advertising
background image

Series Series KNAR/F, KNARP/F, KNAR-D/F, KNARP-D/F,

Page 7

KNAR-S/F, KNARP-S/F

ASME

9520-082-en

Revision 04

TM 7377

Edition 11/2008

2

Notes on safety

This

operating

manual

contains

fundamental

information which is to be observed during installation,
operation and maintenance.
It must therefore be read before installation and
commissioning!

For valves which are used in potentially explosive
areas, see Section 3.
Installation, operation and maintenance are to be
performed by qualified staff.
The area of responsibility, authority and supervision of
the staff must be regulated by the customer.

General hazard symbol!
People may be put at risk.

Safety symbol! The valve and its function
may be put at risk if this safety symbol is not
observed.

It is imperative to observe warnings and signs
attached directly to the valve and they are to be kept
fully legible.
Non-observance of the notes on safety may result
in the loss of any and all claims for damages.
For example, non-observance may involve the
following hazards:

Failure of important functions of the valve/plant.
Risk to people from electric, mechanical and
chemical effects.
Risk to the environment through leaks of hazar-
dous substances.

2.1 Intended use

Ball valves are on/off valves.
Richter ball valves are pressure containing compo-
nents in accordance with the Pressure Equipment
Directive (PED) for the passage and shut-off of fluids.
The valves are suitable for vapours, gases and non-
boiling liquids of group 1 according to the PED and
have a corrosion-resistant plastic lining.
Solids can lead to increased wear, damage to sealing
surfaces or to a reduction in the service life of the
valve.
The operator must carefully examine in the event of
operating data other than those provided whether the
designs of the valve, accessories and materials are
suitable for the new application (consult the manufac-
turer).
Ball valves of the series KNAR-S/F and KNARP-S/F
are preferred for corrosive atmosphere and in clean-
room conditions.

2.2 For the customer / operator

If a valve is used, the operator must ensure that

actuators which are retrofitted are adapted to suit
the valve
hot or cold valve parts are protected by the
customer against being touched
the valve has been properly installed in the pipe
system
the usual flow rates are not exceeded in continuous
operation.

This is not the manufacturer's responsibility.
Loads caused by earthquakes were not allowed for in
the design.

Ball valves which are used as end valves
must be sealed with a blind flange at the free
connection end and appropriately secured

against unauthorised activation.
Fire protection to DIN EN ISO 10497 is not possible
(plastic lining and plastic components).

2.3 Improper operation

The operational reliability of the valve supplied is only
guaranteed if it is used properly in accordance with
Section 2.1 of this operating manual.

The operation limits specified on the
identification plate and in the pressure-
temperature diagram must under no

circumstances be exceeded.

Advertising