6 installation, 1 flange caps and gaskets, 2 direction of flow and installation position – Richter KKP/FU Series Ball Valves (ISO/DIN) User Manual

Page 8: 3 grounding, 4 test pressure, 7 operation, 1 initial commissioning, 2 improper operation and their consequences, Flange caps and gaskets, Direction of flow and installation position

Advertising
background image

Series KK/F, KKP/F, KK/FU, KKP/FU

Page 8

9520-060-en

Revision 02

TM 7692

Edition 11/2009

6

Installation

Examine valve for in-transit damage, damaged ball
valves must not be installed.
Before installation the valve and the connecting
pipe must be carefully cleaned to remove any dirt,
especially hard foreign matter.
During installation, pay attention to the correct
tightening torque, aligned pipes and tension-free
assembly.

Ensure that a remotely actuated actuator
cannot be accidentally switched on.

6.1 Flange caps and gaskets

Leave protective caps on the flanges until just prior
to installation.

Where there is a particularly high risk of damage to
the plastic sealing surfaces, e.g. if the mating flanges
are made of metal are glass-lined, PTFE-lined gaskets
with a metal inlay should be used. These gaskets are
available as special accessories in the Richter range.

6.2 Direction of flow and

installation position

Installation is independent of the direction of flow.
Any installation position can be chosen.
Exception: with a relief or drain bore, identified with a

direction arrow on the ball valve.

The position of the ball ("open" - "closed") is indicated
by the hand lever or flat pivot point on the stem. (Lever
longitudinal to the valve - open; lever at right angles to
the valve - closed. A stud screw serves as an end
stop).

6.3 Grounding

Grounding is provided by the pipe screws. The valve is
grounded by means of a grounding rope 532.
At the customer's request a setscrew M6 with a hex.
nut and washer will be provided at each flange as an
additional grounding connection.

6.4 Test pressure

The test pressure PT of an open valve must not
exceed the value of 1.5 x PN/PS as per the
identification of the valve.

7

Operation

7.1 Initial commissioning

Normally, the valves have been tested for leaks with
air or water. Prior to initial operation check body
bolting. For torques see Section 1.2.

Unless otherwise agreed, there could be
residual amounts of water in the flow section
of the valve; this could result in a possible

reaction with the medium.
To prevent leaks, all connection screws should be
retightened after the initial loading of the valve with
operating pressure and operating temperature.
For torques see Section 1.2.

7.2 Improper operation and their

consequences

The ball valve is an open/closed valve and is not to
be operated in an intermediate position.
Damage to the seat rings or the ball/stem unit
could occur.
Crystallisation may result in damage to the seat
rings or ball/stem unit. This can be prevented by
heating.
In extreme cases this may cause blocking.
Operation with solids leads to increased wear.
Operating during cavitation leads to increased
wear.
Non-observance of the pressure-temperature
diagram can lead to damage.
Do not subject the lever to heavy loads; the lever or
ball valve may be damaged.
Do not use a lever extension as otherwise there is
a risk of damage.

Advertising