5 transport, storage and disposal, 1 storage, 2 return consignments – Richter KNAP-S/F Series Ball Valves (ASME) User Manual

Page 9: 3 disposal, German clean air act (ta luft), Storage, Return consignments, Disposal, 5transport, storage and disposal, Series kna/f, knap/f, kna-d/f, knap-d/f

Advertising
background image

Series KNA/F, KNAP/F, KNA-D/F, KNAP-D/F,

Page 9

KNA-S, KNAP-S,

ASME

9520-080-en_USA

Revision 10

TM 8361

Edition 10/2011

4

Safety note for valves, certified to German Clean Air Act
(TA Luft)

On request, this valve can be supplied compliant with
the German Clean Air Code.
Certificate / Manufacturer Declaration Validity is
dependent on the operating instructions being read
and observed.

In particular, servicing must be conducted at regular
intervals, and the bolted connections relevant for
tightness must be inspected and retightened if
necessary.

5

Transport, storage and disposal

It is imperative, for all transport work, to
observe generally accepted engineering
practice and the accident prevention
regulations.

The valve is supplied with flange caps. Do
not remove them until just before installation.
They protect the plastic surfaces against dirt
and mechanical damage.

Handle the goods being transported with care. During
transport the valve must be protected against impacts
and collisions.
Directly after receipt of the goods, the consignment
must be checked for completeness and any in-transit
damage.
Do not damage paint protection.

5.1 Storage

If the valve is not installed immediately after delivery,
it must be put into proper storage.
It should be stored in a dry, vibration-free and well-
ventilated room at as constant a temperature as
possible.
Elastomers are to be protected against UV light.
In general, a storage period of 10 years should not be
exceeded.

5.2 Return consignments

Valves which have conveyed aggressive or
toxic media must be well rinsed and cleaned
before being returned to the manufacturer's

works.

Observe appropriate safety
precautions when cleaning
the valves of toxic or

aggressive media. Appropriate safety clothing and
equipment should be worn at all times when working
with toxic media!
It is imperative to enclose a safety information
sheet / general safety certificate
on the field of
application with the return consignment.
Pre-printed forms are enclosed with the installation
and operating manual.
Safety precautions and decontamination measures
are to be mentioned.

5.3 Disposal

Parts of the valve may be contaminated with medium
which is detrimental to health and the environment
and therefore cleaning is not sufficient.

Risk of personal injury or damage to the
environment due to the medium!

Wear protective clothing when work is performed
on the valve.
Prior to the disposal of the valve:
Collect any medium, etc. which has escaped and

dispose of it in accordance with the local regu-
lations.

Neutralise any medium residues in the valve.
Separate valve materials (plastics, metals, etc.)
and dispose of them in accordance with the local
regulations.

Advertising