Series SR/F, SR-B/F, SRV/F, SRV-B/F, SRZ-V/F

Page 4

9550-060-en Revision 00
TM 7173

Edition 06/2008

1.2 Type plate, CE and body

markings

The stainless steel name plate is undetachably riveted
to the body.
If the operator attaches his identification, it must be
ensured that the valve matches the application in
question.
Example of name plate with CE marking

No CE marking is permissible for the size 25; the
name plate therefore has no CE marking.

Body identification:
The following are visible on the body according to DIN
EN 19 and AD 2000 A4:

Nominal size
Rated pressure
Body material
Manufacturer's identification
Melt number/Foundry identification
Cast date
Arrow for direction of flow

1.1 Tightening

torques

All screws greased, tighten in diametrically
opposite sequence!
The tightening torques for pipe screws and cover
screws mentioned must not be exceeded.
The following tightening torques are recommended:
Pipe screws, flanges to DIN/ISO

Nominal

size

Screws

Tightening

torque

[mm]

[DIN/ISO]

[Nm]

25

4 x M 12

10

40

4 x M 16

20

50

4 x M 16

26

80

8 x M 16

25

100

8 x M 16

35

Pipe screws, flanges ISO/DIN, drilled to ASME Class
150

Nominal size

Screws

Tightening torque

[mm]

[inch]

[ASME]

[in-lbs]

[Nm]

25

1

4 x ½“

70

8

40

4 x ½“

135

15

50

2

4 x J“

220 25

80 3 4

x

J“

400 45

100 4 8

x

J“

310 35

Cover screws

Nominal

size

Screws

Tightening

torque

[mm]

[DIN/ISO]

[Nm]

25

4 x M 12

25

40

4 x M 16

50

50

4 x M 16

50

80

8 x M 16

50

100

8 x M 16

50

1.3 Flow

rates

SR/F, SR-B/F,

SRV/F, SRV-B/F

SRZ-V/F

Nominal size

Kv 100

Kv 100

[mm]

[m3/h]

[m3/h]

25 15

10

40 35

--

50 50

35

80 125

--

100 170

--

1.4 Minimum

differential

pressures

Installation position

horizontal

vertical

SR/F

1 bar

20 mbar

SR-B/F

1 bar

20 mbar

SRV/F 0,5

bar

10

mbar

SRV-B/F 0,5 bar

10 mbar

SRZ-V/F

5 mbar

If the SRV/F, SRV-B/F and SRZ-V/F is installed as
ventilation valve, it will close from a density of 1
kg/dm

3

upwards.