The command list for parallel mode


Please note that negative logic is used for all commands – an ‘active’ input is pulled
down to the ground (0v) rail. The directions of movement are based on an inverted image
and with the AO unit arranged with its North-South axis at 90 degrees to the Declination
axis.

Guiding functions

East North South West

Function

0

0

0

0

Find Centre /

Switch from

serial to parallel

mode

1

1

1

0

AO West

1

1

0

1

AO South

1

0

1

1

AO North

0

1

1

1

AO East

0

0

0

1

Mount West

0

0

1

0

Mount South

0

1

0

0

Mount North

1

0

0

0

Mount East

0

0

1

1

Force low

motor speed

1

1

0

0

Enter set up

mode

Set up mode functions

1

1

1

0

West motor

forward

1

1

0

1

South motor

forward

1

0

1

1

North motor

forward

0

1

1

1

East motor

forward

1

0

1

0

West motor

back

1

0

0

1

South motor

back

0

1

1

0

North motor