Description: The House Control 406 operates two water source heat pumps in heating or cooling mode to supply an outdoor
reset water temperature to 4 on board mix temperature zones and 4 tank zones connected to the Tank expansion terminals
with a Wiring Center 313. The 406 also operates a modulating condensing boiler to supply an outdoor reset water temperature
to 4 boiler zones connected to the Boil expansion terminals with a Wiring Center 314. The boiler supplies backup heat to the
tank loop using the transfer pump P7.
Mixing is useful to separate the hot and cold water temperatures required for fancoils from the warm and cool temperatures
required for radiant floor heating and cooling. The Variable Speed Pump P1 is able to mix the water temperature down for
heating or mix the water temperature up above the dewpoint for floor cooling.

Expansion

Tank

Mechanical

A406-5

S1

S2

S5

P3

tekmarNet

®

2 Thermostats

tekmarNet

®

2 Thermostats

P2

Z1

Z2

Z3

Z4

P5

Z9

Z10 Z11 Z12

Backup:
Mod Con
Boiler

P6

S3

A1

P1

Z5

Z6

Z7

Z8

P7

P4

S4

tekmarNet

®

2 Thermostats

Two

Water to Water

Heat Pumps

IMPORTANT

When a three water temperature application is selected (WATER TEMP = T+MB), either the Mix or Boiler bus is limited to
the 4 tN2 on board thermostats, and the gateway controls 482 and 483 are unable to communicate to the four on-board tN2
zones on the House Control 406.

WATER TEMP

T+MB (tank + mix + boiler)

ZONES 1-4

MIX

BACKUP

XFER (transfer pump)

BOIL TYPE

0-10

HP LOOP

INT

HP TYPE

ROT (rotate)

DHW MODE

4

Application Settings

P1

Variable Speed Pump

P2

HP Loop Pump

P3

Boiler System Pump

P4

Tank System Pump

P5

Mix System Pump

P6 DHW

Pump

P7

Transfer Pump

S1

Outdoor Sensor

S2

HP Return Sensor

S3

Boiler Sensor

S4

Tank Sensor

Legend

314

406

313

S5

Mix Sensor

A1

DHW Aquastat

Advertising