Wiring to Switching Relay

Zone Pump

L

N

115 V (ac)

W

(T)

(T)

R

24 V

W

(T)

(T)

R

H

N

X

X

H

N

H

N

N

H

Com

Switching Relay

Zone 1

Zone 2

Zone 3

Class 2

Transformer

W

(T)

(T)

R

Meets Class B:
Canadian ICES
FCC Part 15

Made in
Canada

Apr 2010
Lot 1234

24 V ±10% 50/60 Hz 1.6 VA.
24 V (ac) 2 A Class 2

Power:
Relay:

954-01

Thermostat 507

One Stage Heat

507

For 3 wires,
install jumper
R to Rh

2

1

CR

Rh

W

34

24 V

Wiring Examples

MENU BUTTON

The menus display in the Menu Field at the left of the LCD.
Two menus are available:

• View
• Adjust

To select a menu, press and release the Menu button.

ITEM BUTTON

In each menu, a group of items can be selected. The abbreviated name of the selected
item displays in the Item field of the LCD display.

• To view the next available item, press and release the Item button.
• To view the previous item, hold down the Item button and press and release the Up

button.

ADJUSTING A SETTING

To adjust a setting:
1. Use the Menu button to select the appropriate menu.
2. Use the Item button to find the desired setting.
3. Use the Up or Down button to adjust the setting.

115 V (ac)
24 V (ac)

User Interface