If your thermostat has a floor sensor connected to it, floor temperature can be
maintained. This allows you to have warm floors even during milder times of the year
when the air temperature is warm enough or when your air conditioning is on.

Floor temperature can be maintained in two ways. Air temperature can be ignored
and the thermostat will maintain Floor Temperature Only. Or, air temperature can be
considered and the thermostat will maintain Floor and Air Temperatures together.

Floor Temperature Only --------------------------------------------

--------------------------------------------

If the air sensor has been disabled, the thermostat will only maintain floor temperature
and ignore air temperature. In this mode, the desired floor temperature can be
adjusted as described in the “Temperature Adjustment” section.

Floor and Air Temperature

------------------------------------------

------------------------------------------

If the air sensor is turned on and their is a floor sensor connected, the thermostat
will maintain your desired air temperature as well as a minimum floor temperature.
However, the floor minimum temperature will override the air temperature, and if set
too high, may overheat the room. The FLOOR MINIMUM temperature is adjusted
through the Adjust Menu as follows:

Floor Temperatures

Step 1:

Press and hold the and buttons to enter the Adjust Menu, and
wait until the FLOOR MIN setting is shown as well as the desired day

or night

symbol (a new screen will appear every 2 seconds).

Step 2:

Press the or button to adjust the temperature setting.

Step 3:

Release all buttons and wait for the display to return to normal operation.
The adjusted settings will be saved in memory.