Dip switch settings, Led status indicators cleaning the control, Zone group pump – tekmar 337 Dual Zone Manager User Manual

Page 3: Zone group pump delay, Power led, Zone leds, Zone group pump leds

Advertising
background image

3 of 4

© 2005

D 337 - 06/05

DIP Switch Settings

The DIP switches are found on the right hand side of the 337.

LED Status Indicators

Cleaning the Control

The control’s exterior can be cleaned using a damp cloth. Moisten the cloth with water and wring out prior to wiping the
control. Do not use solvents or cleaning solutions.

Dual Zone Manager 337

Meets Class B: Canadian

ICES & FCC Part 15

Made in
Canada

Power Fuse: T15 A 250 V

15 A

Zone A1

Zone A2

Power

Zone Group Pump A

Zone A3

Zone B1

Zone B2

Zone B3

tN4

tektra 996-02

For product instructions, see brochure
Input Power: 115 V (ac) ±10% 60 Hz, 15.5 A
Relay Rating: 115 V (ac) 5 A
All Loads Using Input Power: 15 A

Caution! Disconnect All
Power before Opening

Limited power available, see wiring brochure

For product literature:
www.tekmarcontrols.com

Zone Group Pump B

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

20

H7005B

32

33

34

35

36

37

38

39

40

41

42

43

17

18

19

21

22

23

24

25

26

27

24 V (ac) Fuse: T2.5 A 250 V

28

29

30

31

On/Off

Zone Group

Pump A Delay

Zone Group

Pump A

Zone Group

Pump B Delay

Zone Group

Pump B

A1
A2
A3
B1
B2
B3
A1
A2
A3
B1
B2
B3

tN4

C

C

C

W

W

R

R

Pmp tN4

tN4

C

W

R

tN4

C

W

R

R

tN4

C

W

tN4

R

C

W

tN4

Input Power

Zn Grp Zn Grp

Zone A1

Zone A2

Zone A3

Zone B1

Zone B2

Zone B3

Zn Grp B

B

tNt

Zone A1

tNt

Zone A2

tNt

Zone A3

tNt

Zone B1

tNt

Zone B2

tNt

Zone B3

N

L

Pmp A

Pmp B

C

Vlv

C

Vlv

C

Vlv

C

Vlv

C

Vlv

C

Vlv

Supply /signal wires 90°C min.

24 V (ac) Fuse: T2.5 A 250 V

On/Off

Zone Group

Pump A Delay

Zone Group

Pump A

Zone Group

Pump B Delay

Zone Group

Pump B

A1
A2
A3
B1
B2
B3
A1
A2
A3
B1
B2
B3

Dual Zone Manager 337

Zone A1

Zone A2

Power

Zone Group Pump A

Zone A3

Zone B1

Zone B2

Zone B3

Zone Group Pump B

Zone Group Pump

Each zone has a corresponding Zone Group Pump DIP
switch.

Zone Group Pump DIP switch set to On:
•

• The Zone Group Pump turns on when the zone calls for

heat.

Zone Group Pump DIP switch set to Off:
•

• The Zone Group Pump does not turn on when the zone

calls for heat.

Zone Group Pump Delay

Each zone has a corresponding Zone Group Pump Delay
DIP switch.

Note: The Zone Group Pump Delay only operates if the
Zone Group Pump DIP switch is set to On.

Zone Group Pump Delay DIP switch set to On:
•

• The Zone Group Pump turns on 3 minutes after the zone

calls for heat

•

• The Zone Group Pump turns off 15 seconds after the

zone stops calling for heat.

Zone Group Pump Delay DIP switch set to Off:
•

• The Zone Group Pump turns on when the zone calls for

heat.

•

• The Zone Group Pump turns off when the zone stops

calling for heat.

Power LED

Green:
•

• Normal operation.

Amber:
•

• Power is present but the fuse for the internal 24 V (ac)

transformer is blown.

Off:
•

• No power to the Power Input of the Zone Manager.

Zone LEDs

Green:
•

• The zone is on.

Off:
•

• The zone is off.

Zone Group Pump LEDs

Green:
•

• The Zone Group Pump relay is on.

Off:
•

• The Zone Group Pump relay is off.

Nine LEDs to provide the status of the 337’s outputs.