EVOLVE 55D PUMP OPERATION / MAINTENANCE MANUAL

5

TROUBLESHOOTING

Pump Will Not Start, Fails to Operate

Cause:

Solution:

•

Insufficient air pressure.

•

Must be minimum 20 psig at pump air connection.

•

Insufficient air volume (low supply
pressure during running).

•

See Performance Charts (3.1) for requirements. Check
for both regulator and control valve C

v

s >.85 capabilities.

•

Fluid discharge line blocked.
Downstream valve closed, filter plugged
or other obstruction.

•

Remove obstruction.

•

Pilot valve failure.

•

Inspect and replace pilot valve assembly.

•

Detent failure.

•

Inspect detent legs for worn or damaged parts.

Bubbles in Fluid Discharge

Cause:

Solution:

•

Leaking fluid inlet fitting.

•

Tighten fittings or replace adapter seal.

•

Leaking main seal.

•

Tighten heads to 125 ft.-lbs.

Replace diaphragms

Check head and body grooves for nicks or scratches.

•

Pump inlet line pressure reached
saturation point (due to high suction
requirement).

•

Increase diameter of suction supply line (reduces
restriction).

Reduce output flow.

•

Ruptured (perforated) diaphragm.

•

Replace diaphragms.

•

Check bore caps leaking.

•

Tighten check bore caps or replace seals.

Fluid Leaks

Cause:

Solution:

•

Leaking main seal.

•

Tighten heads to 125 ft.-lbs.

Replace diaphragms.

Check head and body seal grooves for nicks and
scratches.

•

Check bore cap.

•

Tighten, or remove and replace seal.

•

Ruptured diaphragm(s) can result in
fluid leaks through air exhaust port.

•

Replace diaphragms and any parts that may have been
damaged by fluid exposure.

Erratic Cycling

Cause:

Solution:

•

Pilot valve failure.

•

Inspect and replace pilot valve body and pilot.

•

Suction line restricted (cavitation).

•

Reduce fluid restriction

•

Detent failure.

•

Inspect and replace spool assembly.

•

Check ball(s) not seating.

•

Check O-rings, check balls, and check cages for damage;
replace if necessary.

Make sure check balls move freely in sleeves.

•

Over pressurization of pump discharge.

•

Reduce discharge pressure by reducing restriction.